MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jlcr.3965

Медицинская библиотека · Journal of labelled compounds & radiopharmaceuticals · 2022

Automated radiosynthesis of [11 C]MTP38-a phosphodiesterase 7 imaging tracer-using [11 C]hydrogen cyanide for clinical applications.

Kawamura Kazunori, Hashimoto Hiroki, Ohkubo Takayuki, Hanyu Masayuki, Ogawa Masanao, Nengaki Nobuki, Arashi Daisuke, Kurihara Yusuke, Fujishiro Tomoya, Togashi Takahiro, Sakai Toshiyuki, Muto Masatoshi, Takei Makoto, Ishii Hideki, Saijo Takeaki, Matsumura Takehiko, Obokata Naoyuki, Zhang Ming-Rong

СтатьяПеревод в очереди

Аннотация

We have developed 8-amino-3-(2S,5R-dimethyl-1-piperidyl)-[1,2,4]triazolo[4,3-a]pyrazine-5-[11 C]carbonitrile ([11 C]MTP38) as a positron emission tomography (PET) tracer for the imaging of phosphodiesterase 7. For the fully automated production of [11 C]MTP38 routinely and efficiently for clinical applications, we determined the radiosynthesis procedure of [11 C]MTP38 using [11 C]hydrogen cyanide ([11 C]HCN) as a PET radiopharmaceutical. Radiosynthesis of [11 C]MTP38 was performed using an automated 11 C-labeling synthesizer developed in-house within 40 min after the end of irradiation. [11 C]MTP38 was obtained with a relatively high radiochemical yield (33 ± 5.5% based on [11 C]CO2 at the end of irradiation, decay-corrected, n = 15), radiochemical purity (>97%, n = 15), and molar activity (47 ± 12 GBq/μmol at the end of synthesis, n = 15). All the results of the quality control (QC) testing for the [11 C]MTP38 injection complied with our in-house QC and quality assurance specifications. We successfully automated the radiosynthesis of [11 C]MTP38 for clinical applications using an 11 C-labeling synthesizer and sterile isolator. Taken together, this protocol provides a new radiopharmaceutical [11 C]MTP38 suitable for clinical applications.

Для цитирования: Kawamura Kazunori, Hashimoto Hiroki, Ohkubo Takayuki, Hanyu Masayuki, Ogawa Masanao, Nengaki Nobuki, Arashi Daisuke, Kurihara Yusuke, Fujishiro Tomoya, Togashi Takahiro, Sakai Toshiyuki, Muto Masatoshi, Takei Makoto, Ishii Hideki, Saijo Takeaki, Matsumura Takehiko, Obokata Naoyuki, Zhang Ming-Rong. Automated radiosynthesis of [11 C]MTP38-a phosphodiesterase 7 imaging tracer-using [11 C]hydrogen cyanide for clinical applications.. Journal of labelled compounds & radiopharmaceuticals. 2022. DOI: 10.1002/jlcr.3965.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.