DOI 10.1016/j.ejrad.2026.113040
The added value of 3.0 T quantitative multivoxel proton 1H-MR spectroscopy in the diagnostic work-up of breast lesions.
Аннотация
BACKGROUND
To evaluate whether 3.0 T Multivoxel Proton Magnetic Resonance Spectroscopy (1H-MRS) can reliably and safely rule out malignancy in enhancing breast lesions with a size of at least 8 mm. Reducing the number of false positive (FP) MRI findings is essential to avoid unnecessary biopsies of benign lesions.
METHODS
This prospective study evaluated a consecutive series of 49 enhancing breast lesions ≥ 8 mm using multivoxel 1H-MRS (included 2017-2022). Each lesion's highest choline concentration was calculated and compared across histopathological subtypes. Stratified analysis was performed based on lesion size (<1 versus ≥ 1 cm). Highest choline concentration > 1.70 mmol/L was considered indicative of malignancy. ROC curves, sensitivity, specificity, negative predictive values (NPV), FP and false negative (FN) values were calculated.
RESULTS
Out of 49 lesions (in women with a mean age of 41, range 23-71), 17 were malignant. The median highest choline (mmol/L, ± IQR, range) was significantly higher in malignant lesions [1.73(±1.14, 0.11-8.24)] compared to benign lesions [0.87 (±0.84, 0.09-6.37)(p = 0.02)]. ROC curve showed an AUC of 0.70(95%-CI 0.54-0.87). Using a cut-off value of 1.70 mmol/L sensitivity was 59%, specificity 91%, and NPV 81% across all lesions. In lesions ≥ 1 cm (n = 37) only 3 FN and 2 FP cases were found, with a 70% sensitivity, 93% specificity and NPV of 89%. MRS could prevent target ultrasound (n = 9) or ultrasound plus biopsy (n = 6) in benign enhancing breast lesions ≥ 1 cm.
CONCLUSION
3.0 T 1H-MRS shows promising diagnostic performance in differentiating malignant from benign BI-RADS 3-5 breast lesions ≥ 1 cm. In smaller breast lesions the performance of MRS seems insufficient.