MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/02692155241305250

Медицинская библиотека · Clinical rehabilitation · 2024

Reliability and Optimal Cut-Off Points of the Test for Upper Limb Apraxia (TULIA) for Spanish-Speaking Post-Stroke Patients.

Sánchez-Bermejo Laura, Milla-Ortega Pedro Jesús, Pérez-Mármol José Manuel

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the reliability, identify the optimal cut-off points, and determine the diagnostic accuracy of the TULIA Apraxia test in a sample of Spanish-speaking post-stroke patients.

DESIGN

Cross-sectional.

SETTING

Public primary care.

PARTICIPANTS

201 post-stroke patients.

MAIN MEASURES: Reliability was assessed using Cronbach's alpha. Cut-off points were identified for each TULIA Apraxia sub-test and stratified for age (≤65 years, > 65 years) using ROC curve analysis, area under the curve, and Youden index. Diagnostic accuracy was evaluated using sensitivity, specificity, and predictive values.

RESULTS

Cronbach's alpha of the sub-tests varied from 0.716 (95% CI 0.653-0.772) for pantomime intransitive to 0.824 (95% CI 0.784-0.858) for imitation non-symbolic. Cut-off points ranged from ≤25 to ≤35 points. For individuals aged ≤65 years, the cut-offs that best balanced sensitivity and specificity were ≤25 points for detecting alterations in imitation transitive and ≤33 points for pantomime non-symbolic. For individuals over 65 years, the imitation transitive cut-off (≤26 points) presented the most adjusted balance. The minimum positive predictive value was 0.667 (95% CI 0.542-0.777), indicating that the TULIA Apraxia tests correctly classified more than 67% of patients with apraxia. The minimum negative predictive value was 0.763 (95% CI 0.644-0.859), showing that the test accurately identified more than 76% of patients without apraxia.

CONCLUSIONS

The TULIA Apraxia test is reliable in Spanish-speaking post-stroke patients. Optimal cut-off points, along with their respective sensitivity and specificity values, exhibit adequate test accuracy. Predictive values indicate that the test correctly identifies individuals with and without apraxia.

Для цитирования: Sánchez-Bermejo Laura, Milla-Ortega Pedro Jesús, Pérez-Mármol José Manuel. Reliability and Optimal Cut-Off Points of the Test for Upper Limb Apraxia (TULIA) for Spanish-Speaking Post-Stroke Patients.. Clinical rehabilitation. 2024. DOI: 10.1177/02692155241305250.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.