DOI 10.1016/j.wneu.2023.07.121
Three-Dimensional Volumetric Magnetic Resonance Imaging Analysis of Syringomyelia Evolution After Posterior Fossa Decompression for Chiari Malformation Type1.
Аннотация
OBJECTIVE
This study aims to introduce a method of three-dimensional (3D) volume magnetic resonance imaging (MRI) measurements to evaluate the evolution of syringomyelia (SM) in adults with Chiari malformation type 1 (CM-1) after posterior fossa decompression (PFD), to provide reproducible and accurate measurements.
METHODS
Radiologic and clinical data were obtained for 28 patients. MRI 3D syrinx volumes were evaluated by 2 observers using Philips Healthcare Tumor Tracking tool.
RESULTS
The mean SM preoperative volume was 9.1 ± 15.3 cm3 versus 4.6 ± 8.7 cm3 postoperatively, corresponding to a volume variation reduced by -50% ± 33.4%. A total of 21 patients (75%) showed >25% reduction in SM volume postoperatively and 25 patients (89.2%) showed good to excellent postoperative clinical outcomes. Very high interobserver and intraobserver agreement was noted for 3D volumetric analysis with Cohen weighted κ coefficients (0.899-0.991). A negative correlation was found between the number of involved metameres and the postoperative SM volume reduction (Pearson correlation coefficient = 0.378; P = 0.047). Patients with better clinical outcomes had fewer syrinx septae (F = 8.830; P = 0.001). Similarly, better syrinx volume reduction was associated with fewer septae (F = 1.554; P = 0.233). A positive relationship was observed between clinical outcomes and postoperative syrinx volume reduction (F = 1.554; P= 0.233), with data similar to the reported literature.
CONCLUSIONS
This study shows that 3D volume measurement of the syrinx cavity on MRI is a reproducible and accurate method to assess the postoperative evolution of SM in CM-1 after PFD. Most patients (75%) showed a reduction of SM volume, with a mean volume decrease of 50%. The reliability is yet to be validated in further larger studies.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.