MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1302/0301-620x.101b5.bjj-2018-1478.r1

Медицинская библиотека · The bone & joint journal · 2019

Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? A cardiac MRI survey.

Juneau D, Grammatopoulos G, Alzahrani A, Thornhill R, Inacio J R, Dick A, Vogel K I, Dobransky J, Beaulé P E, Dwivedi G

СтатьяПеревод в очереди

Аннотация

AIMS: Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied.

PATIENTS AND

METHODS

In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements.

RESULTS

None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time.

CONCLUSION

Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540-546.

Для цитирования: Juneau D, Grammatopoulos G, Alzahrani A, Thornhill R, Inacio J R, Dick A, Vogel K I, Dobransky J, Beaulé P E, Dwivedi G. Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? A cardiac MRI survey.. The bone & joint journal. 2019. DOI: 10.1302/0301-620x.101b5.bjj-2018-1478.r1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.