MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rct.0000000000001773

Медицинская библиотека · Journal of computer assisted tomography · 2025

Novel Edge-on-irradiated Si-based Photon-counting Detector CT for the Characterization of Cystic Renal Lesions.

Schwartz Fides R, Yin Zhye, Rui Xue, Bache Steve, Samei Ehsan, Stevens Grant M, Salyapongse Aria M, Szczykutowicz Timothy P, Marin Daniele

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate an edge-on-irradiated silicon-based photon-counting detector CT (Deep Si-PCD-CT) prototype for quantification of iodine concentration and stability of HU values, as well as detectability of subtle features in simulated kidney parenchyma.

MATERIALS AND

METHODS

A phantom, simulating moderately and strongly enhancing kidney parenchyma (at 180 and 240 HU) inside a small, medium, and large patient (23, 30, 37 cm diameter, respectively), was scanned on a Deep Si-PCD-CT. Centered in the kidney parenchyma was a water-equivalent rod at 0 HU and a rod of 0.8 mg/mL iodine concentration to simulate a benign, mildly enhancing cystic renal lesion, as well as a rod with a 2 mm septum and 5 mm mural nodule. Accuracy and stability of HU values were evaluated with repeated ROI measurements across consecutive slices, while the septum and nodule were identified on standard polychromatic clinical images and iodine maps. Images were reconstructed with a soft tissue kernel at 0.417- and 0.625-mm slice-thickness without additional denoising.

RESULTS

Deep Si-PCD-CT produced accurate HU value measurements for water, intralesional iodine content, and renal parenchymal enhancement. The HU values were similarly variable from the ground truth values as compared with measurements from a commercial energy-integrating detector CT. The nodule and septum inside the phantom were successfully identified using the new Deep Si-PCD-CT prototype, while they were difficult to identify using the standard EID-CT at clinical window-level settings. The iodine maps created from the photon-counting detector CT displayed both the nodule and the septum well, facilitating quick identification.

CONCLUSIONS

Deep Si-PCD-CT is a promising tool for the accurate measurement of HU values, as well as the detection of subtle features of complexity in cystic renal lesions. It has the potential to improve the diagnosis and management of cystic renal lesions.

Для цитирования: Schwartz Fides R, Yin Zhye, Rui Xue, Bache Steve, Samei Ehsan, Stevens Grant M, Salyapongse Aria M, Szczykutowicz Timothy P, Marin Daniele. Novel Edge-on-irradiated Si-based Photon-counting Detector CT for the Characterization of Cystic Renal Lesions.. Journal of computer assisted tomography. 2025. DOI: 10.1097/rct.0000000000001773.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.