OBJECTIVES

Measurement of endometrial thickness is an important tool in the assessment of women with postmenopausal bleeding, but the role of endometrial thickness measurement by ultrasound in asymptomatic women is unclear. The aims of this study were to determine: (1) the normal endometrial thickness measured by ultrasonography, (2) the prevalence of serious endometrial pathology and (3) the sensitivity and specificity of endometrial thickness measurement by transvaginal ultrasonography (TVS) for diagnosing premalignant and malignant endometrial disease in asymptomatic postmenopausal women.

METHODS

A MEDLINE and EMBASE search (from inception to January 2011) was performed. Articles reporting on endometrial thickness measurement in the diagnosis of endometrial carcinoma and atypical hyperplasia in asymptomatic postmenopausal women not using hormone replacement therapy (HRT) were selected. Endometrial thickness and the prevalence of endometrial (pre)malignancies were recorded. If possible, 2 × 2 tables were extracted.

RESULTS

Thirty-two studies reporting on 11100 women were included. The estimated mean endometrial thickness was 2.9 mm (95% CI, 2.6-3.3 mm). The pooled estimated prevalences of endometrial carcinoma and atypical endometrial hyperplasia were 0.62% (95% CI, 0.42-0.82%) and 0.59% (95% CI, 0.22-0.96%), respectively. Summary estimates for sensitivity and specificity of TVS endometrial thickness measurement in the prediction of endometrial carcinoma were 0.83 (95% CI, 0.19-1.00) and 0.72 (95% CI, 0.23-0.95) for a 5-mm cut-off and 0.33 (95% CI, 0.04-0.85) and 0.94 (95% CI, 0.92-0.96) for a 6-mm cut-off.

CONCLUSIONS

The results from this systematic review do not justify the use of endometrial thickness as a screening test for endometrial carcinoma and atypical endometrial hyperplasia in asymptomatic postmenopausal women not using HRT.

Для цитирования: Breijer M C, Peeters J A H, Opmeer B C, Clark T J, Verheijen R H M, Mol B W J, Timmermans A. Capacity of endometrial thickness measurement to diagnose endometrial carcinoma in asymptomatic postmenopausal women: a systematic review and meta-analysis.. Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology. 2012. DOI: 10.1002/uog.12306.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.