MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2450/2010.0057-10

Медицинская библиотека · Blood transfusion = Trasfusione del sangue · 2010

Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.

Okutsu Miho, Ohto Hitoshi, Yasuda Hiroyasu, Kawabata Kinuyo, Ono Satoshi, Saito Shunnichi, Sugawara Akiko, Kikuchi Masami, Miura Saori, Ishii Youko, Watanabe Kazuya, Tohyama Yuriko, Nollet Kenneth E

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The indirect antiglobulin test (IAT) can be potentiated by agents such as polyethylene glycol (PEG-IAT) and albumin (Alb-IAT). PEG-IAT is generally regarded as superior to Alb-IAT for the detection of clinically significant red blood cell (RBC) antibodies. However, supporting data come from Caucasian-dominant populations. Non-Caucasian populations should be investigated as well.

MATERIAL AND

METHODS

In this single-centre, retrospective, sequential study, Alb-IAT was used from 1989 to 1996 (8 years) and PEG-IAT from 1997 to 2008 (12 years). Pre-transfusion RBC alloantibody detection rates and specificity, post-transfusion alloantibody production, and the incidence of delayed haemolytic transfusion reaction were assessed and compared for the two periods.

RESULTS

Although overall RBC alloantibody detection rates were comparable, PEG-IAT more frequently detected clinically significant antibodies such as anti-E, anti-Fy(b), and anti-Jk(a), and less frequently detected insignificant antibodies such as anti-Le(b) and anti-P(1). New alloantibodies emerged comparably during the two periods. Delayed haemolytic transfusion reaction was less frequent during the PEG-IAT period (0.30% versus 0.12%, p<0.05).

CONCLUSION

PEG-IAT was superior in the detection of clinically significant antibodies, reduced the detection of insignificant antibodies, and prevented delayed haemolytic transfusion reaction better than Alb-IAT among Japanese transfusion recipients in this retrospective survey of limited power.

Для цитирования: Okutsu Miho, Ohto Hitoshi, Yasuda Hiroyasu, Kawabata Kinuyo, Ono Satoshi, Saito Shunnichi, Sugawara Akiko, Kikuchi Masami, Miura Saori, Ishii Youko, Watanabe Kazuya, Tohyama Yuriko, Nollet Kenneth E. Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.. Blood transfusion = Trasfusione del sangue. 2010. DOI: 10.2450/2010.0057-10.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.