Comparison of six serum analyte workflows using routine liquid chromatography-tandem mass spectrometry methods at multiple laboratories with the Cobas i 601 analyzer, an automated mass spectrometry system.

Vermeersch Pieter, de Jonge Robert, Miyazawa Takamaro, Nybo Mads, Fruekilde Palle, Toole Barry J, Metz Philippe, Albrecht Eva, Slusarczyk Karl, Vogeser Michael, Fitzgerald Robert L

СтатьяСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) offers substantial analytical advantages over traditional immunoassay methods, including greater specificity and robustness. Conventional LC-MS/MS methods are labor-intensive, requiring highly trained, dedicated laboratory staff. The Cobas® i 601 analyzer (Roche Diagnostics International Ltd., Rotkreuz, Switzerland) is an automated, random-access, mass spectrometry (MS) system designed to improve workflows and reduce turnaround times. This study evaluated turnaround times for analyses with the i 601 analyzer vs. routine LC-MS/MS using batch processing.

METHODS

We performed a workflow analysis for six sets of analytes (mycophenolic acid, antibiotics, antiepileptics, voriconazole, testosterone, and 25-hydroxyvitamin D) in seven laboratories across Europe, North America, and Asia. We recorded batch size, result turnaround times, and hands-on times (including quality control) for 93 batches analyzed on routine LC-MS/MS. These were compared to equivalent measurements generated using the i 601 analyzer in batch mode as part of a prototype pilot study at Ludwig Maximilian University, Munich.

RESULTS

Turnaround times were shorter with the i 601 analyzer vs. routine LC-MS/MS for all tested workflows, independent of batch size and analyte workflow. Median time from batch start to final result availability with the i 601 analyzer was 6.8-fold shorter vs. routine LC-MS/MS (1 h, 34 min vs. 10 h, 37 min, respectively). In addition, median total hands-on time was 19-fold shorter with the i 601 analyzer vs. routine LC-MS/MS (5 vs. 93 min).

CONCLUSIONS

Compared with routine LC-MS/MS methods, the i 601 analyzer substantially reduced turnaround and hands-on times for common analytes, regardless of batch size.

Для цитирования: Vermeersch Pieter, de Jonge Robert, Miyazawa Takamaro, Nybo Mads, Fruekilde Palle, Toole Barry J, Metz Philippe, Albrecht Eva, Slusarczyk Karl, Vogeser Michael, Fitzgerald Robert L. Comparison of six serum analyte workflows using routine liquid chromatography-tandem mass spectrometry methods at multiple laboratories with the Cobas i 601 analyzer, an automated mass spectrometry system.. Clinical chemistry and laboratory medicine. 2026. DOI: 10.1515/cclm-2025-0994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.