m+Medelevator.RU
← Поиск публикаций
Mikrochimica acta · 2026

Development of a monoclonal antibody-based time-resolved fluorescence immunochromatographic assay strip for rapid and quantitative determination of ubiquitin C-terminal hydrolase L1 in serum.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Guo Wenjie, Li Tianxu, Chen Yonghua, Lin Wenyi, Wang Zhiyuan, He Kangjie, Zhou Houfeng, Feng Rui, Zhan Zhenye, Cheng Xiao, He Jing, Van Zundert Andre, Su Jianfen, Zan Jie

Аннотация

Traumatic brain injury (TBI) represents a major global health challenge requiring rapid and accurate diagnostic tools. Current detection methods for ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1), a neuron-specific biomarker with diagnostic significance at serum concentrations exceeding 327 pg/mL, face limitations in operational complexity and equipment dependency. Herein, we report the development of a monoclonal antibody-based time-resolved fluorescence immunochromatographic assay strip (TRFIA) for rapid and quantitative determination of UCH-L1 in serum. High-affinity antibody pairs were generated via hybridoma technology, and time-resolved fluorescent microspheres (TRFMs) were integrated with lateral flow immunoassay to overcome the limitations of conventional lateral flow platforms. The optimized TRFIA strip demonstrated excellent analytical performance with a linear range of 0.195–12.5 ng/mL (R² = 0.98), a low limit of detection (LOD) of 81.1 pg/ml, and a rapid assay time of 15 min. Intra- and inter-batch coefficients of variation were consistently below 10%, confirming exceptional reproducibility. Specificity analysis revealed minimal cross-reactivity with other TBI-related biomarkers (Tau, S100β, GFAP). Clinical validation using 24 serum samples from mTBI patients and 10 healthy controls demonstrated significant UCH-L1 elevation in TBI cases (AUC = 0.95), confirming the assay’s diagnostic capability. This TRFIA platform offers a portable, cost-effective, and user-friendly solution for point-of-care TBI diagnosis, particularly valuable in resource-limited settings where rapid decision-making is critical. The development represents a significant advancement in TBI diagnostics, providing a complementary tool to enhance diagnostic accuracy while minimizing unnecessary radiation exposure from CT scans.

Предметные рубрики MeSH