DOI 10.1016/j.ijgo.2012.05.023
Assessment of endometrial volume and vascularization using transvaginal 3D power Doppler angiography in women with postmenopausal bleeding.
Аннотация
OBJECTIVE
To compare the usefulness of 3D power Doppler angiography (3D-PDA) and endometrial thickness measurement by 2D Doppler ultrasound in the distinction of benign from malignant disease in postmenopausal women with abnormal uterine bleeding (AUB) and an endometrial thickness greater than 4.5mm.
METHODS
Forty-eight women with AUB and an endometrial thickness greater than 4.5mm on 2D ultrasound underwent 3D-PDA. The endometrium and a 5-mm subendometrial "shell" were evaluated at rotation angles of 9° and 30°. Endometrial volume, vascularity index, flow index, and vascularization flow index were obtained.
RESULTS
The histologic findings were normal or benign for 38 women (79%) and malignant for 10 (21%). All vascular indices were significantly higher in the group with malignancies except for the vascularization flow index. There were no differences in the values obtained using the 9° or the 30° angle. Receiver-operating characteristics curves were traced for all indices. The vascularity index had the best area under the curve (0.78), 77.8% sensitivity, and 82.6% specificity. The areas under the curve were smaller for the shell than for the endometrium.
CONCLUSION
3D-PDA was not found better than 2D ultrasound at distinguishing benign from malignant disease in women with AUB and an endometrial thickness greater than 4.5mm.