MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-023-39062-0

Медицинская библиотека · Scientific reports · 2023

Development and validation of a portable articulated dynamometry system to assess knee extensor muscle strength.

Myong Youho, Park Sungwoo, Cho Minwoo, Cho Seung Yeon, Lee Woo Hyung, Oh Byung-Mo, Kim Sungwan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Muscle strength assessment is important in predicting clinical and functional outcomes in many disorders. Manual muscle testing, although commonly used, offers suboptimal accuracy and reliability. Isokinetic dynamometers (IKDs) have excellent accuracy and reliability; but are bulky and expensive, offering limited accessibility. This study aimed to design a portable dynamometer that is accessible, accurate and reliable, and to validate the device in a general population. The portable articulated dynamometry system (PADS) is a portable device with an embedded high-precision load cell, designed to measure muscle strength with optimal accuracy. Seventy-two participants underwent maximal isometric and isokinetic knee extensor torque measurement with the PADS and IKD, respectively. The PADS results were cross-validated against IKD results using change in mean (CIM). Interrater and intra-rater reliabilities were assessed using intraclass correlation coefficients, standard error of measurement, and minimal detectable change. The PADS maximal knee extensor strength results were not significantly different from those by IKD (CIM: - 2.13 Nm; 95% CI - 4.74, 0.49 Nm). The PADS showed interrater reliability (Pearson's r: 0.958; ICC: 0.979; SEM: 5.51%) and excellent intra-rater reliability (Pearson's r: 0.912; ICC: 0.954; SEM: 8.38%). The proposed PADS may be an effective alternative to IKD, offering good accuracy, reliability, and potentially better accessibility.

Для цитирования: Myong Youho, Park Sungwoo, Cho Minwoo, Cho Seung Yeon, Lee Woo Hyung, Oh Byung-Mo, Kim Sungwan. Development and validation of a portable articulated dynamometry system to assess knee extensor muscle strength.. Scientific reports. 2023. DOI: 10.1038/s41598-023-39062-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.