[The causes and preventive methods of misdiagnosis on wrist scaphoid bone fracture].
Аннотация
OBJECTIVE
To retrospectively analysis the curative effect of wrist scaphoid bone fracture,and explore the causes and preventive methods of misdiagnosis.
METHODS
From September 2007 to September 2010,16 patients with wrist scaphoid bone fractures were treated with plaster cast and cannulated screws fixation. There were 10 males and 6 females,ranging in age from 26 to 44 years with an average of 35 years. Among them, 12 cases manifested swelling pain of radial lateral wrist, tenderness at snuffbox area, wrist pain aggravated when stretching wrist joint, thumb or forefinger; 4 cases manifested no obviously symptoms and limited movement; 9 cases were early diagnosed; 5 cases were treated by plaster cast; 4 cases were treated with cannulated screws fixation; Among 7 cases with misdiagnosis, there were 4 cases without obvious symptoms and they were dealt with activating blood to dissipate swelling and pain process in preliminary stage. Four cases were treated with plaster cast and 3 cases with cannulated screws fixation.
RESULTS
All the patients were followed up from 3 months to 39 months (averaged 21 months). Among 16 patients, 9 cases were early diagnosis, 7 cases were misdiagnosis and the rate of misdiagnosis was 43.8%. Seven cases with screws fixation were no wound infection. There was 1 case with occurred chronic pain and declining wrist mobility in both plaster cast and screw group, and both of them were misdiagnosed. According to curative effect rating criteria,these 2 cases were classified into moderate, other 14 cases were excellent.
CONCLUSION
Wrist scaphoid bone fracture are easy to misdiagnose, so early diagnosis and treatment is particularly important. The main causes of misdiagnosis are nonspecific symptoms at early stage, combination with other injuries, lack of knowledge and ignorance of the further examination. Therefore, detailed inquiries and particular examination, multi-dimensional radiography and CT scan or MRI scan are the main measures for prevention.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.