MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/shk.0000000000001634

Медицинская библиотека · Shock (Augusta, Ga.) · 2021

Shock Index and Postpartum Hemorrhage in Vaginal Deliveries: A Multicenter Retrospective Study.

Ushida Takafumi, Kotani Tomomi, Imai Kenji, Nakano-Kobayashi Tomoko, Nakamura Noriyuki, Moriyama Yoshinori, Yoshida Shigeru, Yamashita Mamoru, Kajiyama Hiroaki, Kikkawa Fumitaka

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Shock index (SI), calculated by dividing heart rate by systolic blood pressure, is used to detect hemodynamic instability and hypovolemia. In obstetric practice, limited evidence is available regarding its usefulness in detecting postpartum hemorrhage (PPH). We aimed to evaluate the usefulness of SI in detecting PPH in vaginal deliveries using clinical data from 12 primary maternity care units in Japan.

MATERIAL AND

METHODS

In this multicenter retrospective study, a total of 30,820 women who delivered vaginally at term at 12 primary maternity care units from January 2012 to December 2018 were included. Systolic and diastolic blood pressures and heart rate were measured at five different time points from admission to postpartum 2 h, and postpartum blood loss was measured. We evaluated the trend of average SI and the performance of each vital sign for detection of PPH.

RESULTS

The trend of average SI during labor and the immediate postpartum period was approximately 0.7 in women with blood loss of <500 mL. SI from the time of delivery of the placenta increased with an increase in blood loss. SI had the highest area under the receiver operating characteristic curve of 0.699 [95% confidence interval (CI), 0.682-0.716] and 0.758 (95% CI, 0.729-0.788) for PPH of ≥1,000 and ≥1,500 mL, respectively. However, both sensitivity of SI (1.0) for PPH (≥1,000 mL; 29.9%, and ≥1,500 mL; 40.5%, respectively) and correlation between maximum SI and blood loss (coefficient of correlation, 0.263) were low.

CONCLUSIONS

SI is a better parameter for PPH detection in vaginal deliveries than other vital signs. However, clinical judgment must incorporate other vital signs and symptoms associated with hypovolemic shock due to the low sensitivity of SI.

Для цитирования: Ushida Takafumi, Kotani Tomomi, Imai Kenji, Nakano-Kobayashi Tomoko, Nakamura Noriyuki, Moriyama Yoshinori, Yoshida Shigeru, Yamashita Mamoru, Kajiyama Hiroaki, Kikkawa Fumitaka. Shock Index and Postpartum Hemorrhage in Vaginal Deliveries: A Multicenter Retrospective Study.. Shock (Augusta, Ga.). 2021. DOI: 10.1097/shk.0000000000001634.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.