Heart sounds at home: feasibility of an ambulatory fetal heart rhythm surveillance program for anti-SSA-positive pregnancies.
Аннотация
OBJECTIVE
Fetuses exposed to anti-SSA (Sjögren's) antibodies are at risk of developing irreversible complete atrioventricular block (CAVB), resulting in death or permanent cardiac pacing. Anti-inflammatory treatment during the transition period from normal heart rhythm (fetal heart rhythm (FHR)) to CAVB (emergent CAVB) can restore sinus rhythm, but detection of emergent CAVB is challenging, because it can develop in ⩽24 h. We tested the feasibility of a new technique that relies on home FHR monitoring by the mother, to surveil for emergent CAVB.
STUDY
DESIGN
We recruited anti-SSA-positive mothers at 16 to 18 weeks gestation (baseline) from 8 centers and instructed them to monitor FHR two times a day until 26 weeks, using a Doppler device at home. FHR was also surveilled by weekly or every other week fetal echo. If FHR was irregular, the mother underwent additional fetal echo. We compared maternal stress/anxiety before and after monitoring. Postnatally, infants underwent a 12-lead electrocardiogram.
RESULTS
Among 133 recruited, 125 (94%) enrolled. Among those enrolled, 96% completed the study. Reasons for withdrawal (n=5) were as follows: termination of pregnancy, monitoring too time consuming or moved away. During home monitoring, 9 (7.5%) mothers detected irregular FHR diagnosed by fetal echo as normal (false positive, n=2) or benign atrial arrhythmia (n=7). No CAVB was undetected or developed after monitoring. Questionnaire analysis indicated mothers felt comforted by the experience and would monitor again in future pregnancies.
CONCLUSION
These data suggest ambulatory FHR surveillance of anti-SSA-positive pregnancies is feasible, has a low false positive rate and is empowering to mothers.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.