MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jalm/jfaf204

Медицинская библиотека · The journal of applied laboratory medicine · 2026

Comparison of the Friedewald, Sampson, and Martin Formulas with Direct Homogeneous Assay of Low-Density Lipoprotein Cholesterol in South American Patients.

Fernandez Machulsky Nahuel, Jacobsen Dario, Cardozo Madaf Abi, Fochi Antonella, Gomez Maria Eugenia, Berg Gabriela

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Increases in obesity and hypertriglyceridemia worldwide, together with lower LDL cholesterol (LDL-c) values from new lipid-lowering agents, prompted the development of new estimation formulas including Martin (M-LDL-c), extended Martin (ME-LDL-c), and Sampson (S-LDL-c) equations. These require validation in different populations.

METHODS

Lipid profiles with direct LDL-c (D-LDL-c) by homogeneous assay were collected from 22 748 patients in Argentina. Friedewald (F-LDL-c), S-LDL-c, M-LDL-c, and ME-LDL-c were calculated. Patients were classified into treatment categories using both D-LDL-c and each formula independently. Datasets were subdivided by triglycerides (TG). Lipid ratio plot (LRP) provided indirect comparison to beta quantification (BQ). Passing-Bablok, Bland-Altman, and clinical concordance (kappa index) analyses assessed formula performance against D-LDL-c.

RESULTS

LRP analysis showed S-LDL-c had the closest agreement with BQ surrogate line, followed by D-LDL-c. All formulas showed good correlation with D-LDL-c (r > 0.95) and moderate concordance (kappa > 0.6). M-LDL-c and ME-LDL-c demonstrated the best clinical concordance with D-LDL-c overall. Performance decreased with increasing TG for all formulas. F-LDL-c deteriorated from 200 mg/dL (2.28 mmol/L) TG, while S-LDL-c, M-LDL-c, and ME-LDL-c maintained acceptable performance up to 400 mg/dL (4.56 mmol/L) TG.

CONCLUSION

S-LDL-c, M-LDL-c, and ME-LDL-c showed better agreement with D-LDL-c than F-LDL-c in this South American population. LRP analysis suggests S-LDL-c may provide most accurate estimation vs gold standard BQ, particularly in hypertriglyceridemia. These findings support the adoption of newer equations in clinical practice.

Для цитирования: Fernandez Machulsky Nahuel, Jacobsen Dario, Cardozo Madaf Abi, Fochi Antonella, Gomez Maria Eugenia, Berg Gabriela. Comparison of the Friedewald, Sampson, and Martin Formulas with Direct Homogeneous Assay of Low-Density Lipoprotein Cholesterol in South American Patients.. The journal of applied laboratory medicine. 2026. DOI: 10.1093/jalm/jfaf204.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.