The Role of Phase Angle in Non-Invasive Fluid Assessment in Dogs with Patent Ductus Arteriosus: A Novel Method in Veterinary Cardiology.

Li Zongru, Farag Ahmed, Mandour Ahmed S, Xu Tingfeng, Terai Kazuyuki, Shimada Kazumi, Hamabe Lina, Yokoi Aimi, Yan Shujun, Tanaka Ryou

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patent ductus arteriosus (PDA) in dogs causes persistent left-to-right shunting, leading to pulmonary overcirculation, left heart volume overload, and potential congestive heart failure. Accurate assessment of fluid imbalance is essential but challenging with conventional echocardiography or biomarkers. Phase angle (PhA), derived from bioelectrical impedance analysis (BIA), may serve as a non-invasive marker of extracellular fluid distribution and cellular integrity.

OBJECTIVES

This study aimed to evaluate PhA as an indicator of thoracic fluid imbalance in dogs with PDAby analyzing its correlation with pulmonary velocity (PV) and end-diastolic volume (eV), as well as its responsiveness to surgical correction. In addition, we assessed the relationships between PhA and echocardiographic structural indices (LA/Ao, TDI Sep E/Em, TDI Lat E/Em) and examined the influence of the measurement region.

METHODS

PhA was measured at 5, 50, and 250 kHz in 30 PDA-affected and 15 healthy dogs, with electrode placement across thorax, trunk, and abdomen. Echocardiography evaluated PV, eV, and PDA-specific structural parameters.

RESULTS

Thoracic PhA at 5 kHz was significantly reduced in PDAdogs, strongly correlated with PV and moderately with eV. Postoperative measurements showed progressive PhA recovery. Only TDI Lat E/Em correlated with mid-frequency PhA, while other structural indices showed minimal association. Thoracic PhA was lower than trunk or abdominal values, indicating that thoracic measurements may better capture localized extracellular fluid changes in PDAcompared with other regions.

CONCLUSION

Thoracic PhA at 5 kHz effectively reflects extracellular fluid changes in PDA, complements structural echocardiography, and tracks postoperative fluid normalization. Its non-invasive nature supports clinical utility for monitoring hemodynamic burden and therapeutic response.

Для цитирования: Li Zongru, Farag Ahmed, Mandour Ahmed S, Xu Tingfeng, Terai Kazuyuki, Shimada Kazumi, Hamabe Lina, Yokoi Aimi, Yan Shujun, Tanaka Ryou. The Role of Phase Angle in Non-Invasive Fluid Assessment in Dogs with Patent Ductus Arteriosus: A Novel Method in Veterinary Cardiology.. Veterinary sciences. 2025. DOI: 10.3390/vetsci12101007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.