DOI 10.1109/ojemb.2023.3258362
Validation of a Finite Element Simulation for Predicting Individual Knee Joint Kinematics.
Аннотация
Goal: We introduce an in-vivo validated finite element (FE) simulation approach for predicting individual knee joint kinematics. Our vision is to improve clinicians' understanding of the complex individual anatomy and potential pathologies to improve treatment and restore physiological joint kinematics.
Methods
Our 3D FE modeling approach for individual human knee joints is based on segmentation of anatomical structures extracted from routine static magnetic resonance (MR) images. We validate the predictive abilities of our model using static MR images of the knees of eleven healthy volunteers in dedicated knee poses, which are achieved using a customized MR-compatible pneumatic loading device.
Results
Our FE simulations reach an average translational accuracy of 2 mm and an average angular accuracy of 1[Formula: see text] compared to the reference knee pose.
Conclusions
Reaching high accuracy, our individual FE model can be used in the decision-making process to restore knee joint stability and functionality after various knee injuries.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.