m+Medelevator.RU
← Поиск публикаций
BMC musculoskeletal disorders · 2024

Enhanced bone cement distribution in percutaneous vertebroplasty using a curved guide wire: a propensity score matching analysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hu Xuyan, Zhang Zijin, Yang Yisong, Zhang Gang, Cao Shen, Yu Bing, Zhang Yubing

Аннотация

BACKGROUND: Osteoporotic vertebral compression fractures (OVCF) severely affect the quality of life in the aged population. Percutaneous vertebroplasty (PVP) alleviates pain and stabilizes vertebrae, but suboptimal bone cement distribution can cause complications. Hence, this study aimed to clarify whether a new technique for PVP, using a curved guide wire, enhances the distribution of bone cement and improves clinical outcomes in patients with OVCF.

METHODS: Patients with single-segment OVCF underwent PVP or curved guide wire percutaneous vertebroplasty (C-PVP). Propensity score matching (PSM) was employed to balanced the baseline characteristics. The primary outcomes were the visual analog scale (VAS) and Oswestry disability index (ODI) scores. The secondary outcomes included assessments of bone cement distribution, bone cement injection volume, radiological parameters, and general clinical results. Additionally, Complications and adverse events were documented.

RESULTS: After PSM analysis, each group comprised 54 patients, which significantly reduced baseline differences. The C-PVP group showed better clinical outcomes compared to the traditional PVP group. One month after surgery, the C-PVP group had significantly lower VAS and ODI scores (p < 0.001). These improvements persisted at six months and the final follow-up. Additionally, bone cement distribution scores were better (p < 0.001), injection volume was higher (p = 0.03), leakage was less frequent (p = 0.02), and adjacent vertebral fractures occurred less frequently (p = 0.04) in the C-PVP group. Radiological parameters and overall clinical outcomes revealed no significant differences between the two groups.

CONCLUSION: The use of curved guide wire in PVP significantly improves bone cement distribution and injection volume, resulting in better clinical efficacy in patients with OVCF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты