m+Medelevator.RU
← Поиск публикаций
Journal of neuroengineering and rehabilitation · 2026

SSVEP-based brain-computer interface enabling graded dyspnoea self-report: proof-of-concept study in healthy volunteers.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Campion Sébastien, Navarro-Suné Xavier, Rivals Isabelle, Morélot-Panzini Capucine, Serresse Laure, Chavez Mario, Demoule Alexandre, Niérat Marie-Cécile, Raux Mathieu, Similowski Thomas

Аннотация

BACKGROUND: Mechanically ventilated patients may experience respiratory suffering, which is difficult to assess when verbal communication is impaired. We evaluated the performance of a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) designed to enable self-reporting of dyspnoea in this context.

METHODS: Forty-nine healthy volunteers were studied under five respiratory conditions: normal breathing (NB), inspiratory resistive loading (IRL), inspiratory threshold loading (ITL), CO₂ inhalation (CO₂), and a return to NB as wash-out (NBWO). Respiratory discomfort was evaluated using a visual analogue scale (VAS). Two BCIs models were tested: a detection BCI (D-BCI), designed to discriminate between 'breathing is OK' and 'breathing is difficult', and a quantification BCI in the form of a LED-based analogue scale (LAS), composed of five light-emitting diodes. Visual stimuli were delivered at different frequency sets: 12-15 Hz, 15-20 Hz, and 20-30 Hz for the D-BCI; low frequencies (13-17-19-23-29 Hz) and high frequencies (41-43-47-53-59 Hz) for the LAS. Performance was assessed using receiver operating characteristic (ROC) curves; the area under the ROC curve (AUC) was the primary outcome.

RESULTS: Participants reported significant respiratory discomfort during IRL, ITL, and CO₂ conditions in the D-BCI groups, and during ITL and CO₂ in the LAS groups, as reflected by higher dyspnoea VAS scores compared to NB. The best-performing frequency sets were 20-30 Hz for the D-BCI (AUC 0.89 [0.89-0.90]) and low frequencies for the LAS (AUC 0.84 [0.83-0.85]).

CONCLUSIONS: This study demonstrates that an SSVEP-based BCI can sucessfully detect and quantify experimentally induced dyspnoea in healthy individuals. Further research is needed to evaluate its clinical applicability for assessing dyspnoea in non-communicative patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты