DOI 10.1007/s00464-026-12805-6
The breaking point in robotic pancreaticoduodenectomy: factors influencing conversion thresholds and early postoperative outcomes in a tertiary referral center.
Аннотация
BACKGROUND
Robotic pancreaticoduodenectomy (RPD) has expanded the indications of minimally invasive pancreatic surgery. However, conversion to open surgery remains a relevant intraoperative event, and data on its determinants and clinical impact in real-world robotic programs are limited. Conversion is increasingly regarded as a safety-driven decision rather than a technical failure, particularly in experienced centers.
METHODS
This retrospective single-center cohort study included all consecutive adult patients undergoing intended RPD between April 2018 and October 2025. Conversion was defined as any unplanned laparotomy after initiation of the robotic approach. Patient-, disease-, and procedure-related variables were analyzed. Factors associated with conversion were explored using univariable analyses and multivariable Firth penalized logistic regression. Postoperative outcomes were assessed descriptively according to conversion status using effect size measures.
RESULTS
Among 130 patients undergoing RPD, 16 (12.3%) required conversion. On multivariable analysis, vascular contact requiring resection emerged as the strongest factor associated with conversion, followed by periampullary tumor location, while previous pancreatitis showed a borderline association. Most conversions occurred early in the procedure (75%) and were strategic rather than urgent (87.5%). Conversion was associated with higher intraoperative transfusion rates and increased postoperative resource utilization, including longer hospital and high-dependency unit stay. No clear evidence of a large increase in major postoperative morbidity was observed, and rates of major postoperative complications, pancreatic fistula (grade B/C), and 30-day mortality were similar between groups, although estimates remain imprecise due to the limited number of converted cases.
CONCLUSIONS
In a high-volume robotic pancreatic program, conversion during RPD was primarily driven by anatomical and disease-related complexity rather than surgical inexperience. When performed in a timely and controlled manner, conversion may represent a proactive safety strategy rather than a technical failure, although these findings should be interpreted cautiously given the limited number of conversion events.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.