MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bjs.4513

Медицинская библиотека · The British journal of surgery · 2004

Serum levels of soluble E-selectin in women with breast cancer.

Sheen-Chen S-M, Eng H-L, Huang C-C, Chen W-J

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Increasing evidence suggests that E-selectin contributes to tumour growth and metastasis, possibly by increasing angiogenesis and the adhesion of tumour cells to endothelial cells at distant sites. This study aimed to examine the relationship between preoperative levels of circulating soluble E-selectin and breast cancer.

METHODS

Sixty-four consecutive women undergoing surgery for invasive breast cancer were studied prospectively. Venous blood samples were collected before the operation. A control group consisted of 16 patients with a benign breast tumour (eight with fibrocystic disease and eight with fibroadenoma). Serum concentrations of soluble E-selectin were measured by the quantitative sandwich enzyme immunoassay technique and compared with clinicopathological information.

RESULTS

The mean (s.d.) serum level of soluble E-selectin in patients with invasive breast cancer was 73.7 (20.9) ng/ml, compared with 36.3 (5.6) ng/ml in the control group (P < 0.001). Furthermore, the serum levels of soluble E-selectin were significantly higher in women with oestrogen receptor-negative tumours (P = 0.001), poorly differentiated tumours (P < 0.001), more advanced primary tumour stage (P < 0.001), involved lymph nodes (P < 0.001), distant metastases (P < 0.001) and more advanced tumour node metastasis (TNM) stage (P < 0.001). On multivariate analysis, TNM stage (P < 0.001) was found to be an independent factor with regard to higher serum levels of soluble E-selectin.

CONCLUSION

Preoperative serum levels of soluble E-selectin might reflect the severity of invasive breast cancer; further evaluation is warranted.

Для цитирования: Sheen-Chen S-M, Eng H-L, Huang C-C, Chen W-J. Serum levels of soluble E-selectin in women with breast cancer.. The British journal of surgery. 2004. DOI: 10.1002/bjs.4513.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.