MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/ph18070998

Медицинская библиотека · Pharmaceuticals (Basel, Switzerland) · 2025

Development and Validation of Bioanalytical LC-MS/MS Method for Pharmacokinetic Assessment of Amoxicillin and Clavulanate in Human Plasma.

Lee Sangyoung, Kim Da Hyun, Shin Sabin, Min Jee Sun, Kim Duk Yeon, Jo Seong Jun, Jerng Ui Min, Bae Soo Kyung

СтатьяПеревод в очереди

Аннотация

Background/

Objectives

We developed and validated a robust and simple LC-MS/MS method for the simultaneous quantification of amoxicillin and clavulanate in human plasma relative to previously reported methods.

Methods

Amoxicillin; clavulanate; and an internal standard, 4-hydroxytolbutamide, in human K2-EDTA plasma, were deproteinized with acetonitrile and then subjected to back-extraction using distilled water-dichloromethane. Separation was performed on a Poroshell 120 EC-C18 column with a mobile-phase gradient comprising 0.1% aqueous formic acid and acetonitrile at a flow rate of 0.5 mL/min within 6.5 min. The negative electrospray ionization modes were utilized to monitor the transitions of m/z 363.9→223.1 (amoxicillin), m/z 198.0→135.8 (clavulanate), and m/z 285.0→185.8 (4-hydroxytolbutamide). Results/

Conclusions

Calibration curves exhibited linear ranges of 10-15,000 ng/mL for amoxicillin (r ≥ 0.9945) and 20-10,000 ng/mL for clavulanate (r ≥ 0.9959). Intra- and inter-day's coefficients of variation, indicating the precision of the assay, were ≤7.08% for amoxicillin and ≤10.7% for clavulanate, and relative errors in accuracy ranged from -1.26% to 10.9% for amoxicillin and from -4.41% to 8.73% for clavulanate. All other validation results met regulatory criteria. Partial validation in lithium-heparin, sodium-heparin, and K3-EDTA plasma confirmed applicability in multicenter or large-scale studies. This assay demonstrated itself to be environmentally friendly, as assessed by the Analytical GREEnness (AGREE) tool, and was successfully applied to a clinical pharmacokinetic study of an Augmentin® IR tablet (250/125 mg). The inter-individual variabilities in clavulanate exposures (AUCt and Cmax) were significantly greater than in amoxicillin, and they may inform the clinical design of future drug-drug interaction.

Для цитирования: Lee Sangyoung, Kim Da Hyun, Shin Sabin, Min Jee Sun, Kim Duk Yeon, Jo Seong Jun, Jerng Ui Min, Bae Soo Kyung. Development and Validation of Bioanalytical LC-MS/MS Method for Pharmacokinetic Assessment of Amoxicillin and Clavulanate in Human Plasma.. Pharmaceuticals (Basel, Switzerland). 2025. DOI: 10.3390/ph18070998.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.