MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00234-026-03931-y

Медицинская библиотека · Neuroradiology · 2026

Flow-sensitive black blood sequence in evaluating impairment of cerebral venous drainage in patients with intracranial dural arteriovenous fistulas.

Matsumoto Taiga, Kiyosue Hiro, Uetani Hiroyuki, Kaku Yasuyuki, Takemoto Yushin, Hayashi Hiromitsu, Kumita Shin-Ichiro, Hirai Toshinori

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Intracranial dural arteriovenous fistulas (DAVFs) sometimes cause impaired cerebral venous drainage (ICVD), leading to severe neurological outcomes. While digital subtraction angiography (DSA) is the diagnostic gold standard, the assessment of ICVD through the “pseudophlebitic pattern (PPP)” can be subjective and difficult. This study aimed to evaluate the utility of the flow-sensitive black-blood (FSBB) MRI sequence for detecting ICVD in DAVF patients by comparing it with findings from cerebral angiography. MATERIALS AND

METHODS

We retrospectively analyzed 25 patients with DAVFs who underwent both FSBB MRI and DSA. Two radiologists, an experienced neuroradiologist and a radiology resident, independently evaluated the images. ICVD on FSBB was defined as dilated and tortuous venous structures. Interobserver agreement was calculated using the κ statistic.

RESULTS

FSBB MRI identified signs of ICVD more frequently than DSA revealed PPP for both the neuroradiologist (76% vs. 64%) and the resident (68% vs. 48%). Importantly, interobserver agreement for detecting these findings was higher with FSBB (κ = 0.72) than with angiography (κ = 0.61). FSBB also detected ICVD in cases that were negative for PPP on angiography, suggesting higher sensitivity. Furthermore, of 14 patients who underwent post-treatment imaging, 12 (87.5%) showed improvement in ICVD findings on FSBB, suggesting its utility in monitoring treatment response.

CONCLUSION

FSBB MRI is a highly sensitive and reproducible technique for evaluating ICVD in patients with DAVFs.

Для цитирования: Matsumoto Taiga, Kiyosue Hiro, Uetani Hiroyuki, Kaku Yasuyuki, Takemoto Yushin, Hayashi Hiromitsu, Kumita Shin-Ichiro, Hirai Toshinori. Flow-sensitive black blood sequence in evaluating impairment of cerebral venous drainage in patients with intracranial dural arteriovenous fistulas.. Neuroradiology. 2026. DOI: 10.1007/s00234-026-03931-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.