MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjhci-2025-101526

Медицинская библиотека · BMJ health & care informatics · 2026

Unrecognised sleep disturbances in patients with cirrhosis diagnosed with a portable electroencephalogram device.

Uchiyama Atsushi, Kamimura Hiroteru, Miida Suguru, Maruyama Hiroki, Tonouchi Takafumi, Seol Jaehoon, Kokubo Toshio, Okura Tomohiro, Watanabe Yusuke, Kimura Naruhiro, Abe Hiroyuki, Sakamaki Akira, Yokoo Takeshi, Terai Shuji

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

We aimed to compare sleep characteristics between patients with liver cirrhosis and healthy controls using a standardised protocol and portable electroencephalogram (EEG) devices.

METHODS

We enrolled patients with early stage cirrhosis at low risk for sleep disorders (no apnoea, insomnia, alcohol use, pruritus or major portosystemic shunt; body mass index (BMI) ≤31 kg/m²). Using propensity score matching (age, sex, BMI), 18 patients with cirrhosis were compared with 18 healthy older adults from a 95-person cohort. Sleep was assessed at home using portable EEG devices measuring total sleep time, sleep latency, wake after sleep onset, sleep efficiency, sleep stages (N1-N3, rapid eye movement (REM)) and REM latency. Questionnaires were also administered.

RESULTS

Questionnaires indicated no major sleep complaints. However, EEG revealed longer sleep latency, increased wakefulness and lower sleep efficiency in cirrhosis. N1 sleep time and percentage were higher, REM sleep was reduced and REM latency was prolonged.

DISCUSSION: Traditional assessments rely on subjective reports, while polysomnography is often impractical. Our portable EEG approach revealed distinct disturbances-fragmented REM and delayed onset-undetectable by questionnaires alone.

CONCLUSION

Home EEG monitoring uncovered previously unrecognised sleep abnormalities in cirrhosis, suggesting utility for early detection and management.

Для цитирования: Uchiyama Atsushi, Kamimura Hiroteru, Miida Suguru, Maruyama Hiroki, Tonouchi Takafumi, Seol Jaehoon, Kokubo Toshio, Okura Tomohiro, Watanabe Yusuke, Kimura Naruhiro, Abe Hiroyuki, Sakamaki Akira, Yokoo Takeshi, Terai Shuji. Unrecognised sleep disturbances in patients with cirrhosis diagnosed with a portable electroencephalogram device.. BMJ health & care informatics. 2026. DOI: 10.1136/bmjhci-2025-101526.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.