MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1399-6576.1996.tb04562.x

Медицинская библиотека · Acta anaesthesiologica Scandinavica · 1996

Hemodynamic effects of tracheal and intravenous adrenaline in infants with congenital heart anomalies.

Jonmarker C, Olsson A K, Jögi P, Forsell C

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

If intravenous access cannot be accomplished during cardiopulmonary resuscitation in children, tracheal administration of 100 micrograms/kg of adrenaline (ten times greater than the intravenous dose) is recommended.

METHODS

In a randomized crossover study we recoreded the hemodynamic effect of a low dose of intravenous adrenaline and a ten times greater tracheal dose. While anesthetized for open heart surgery, fourteen infants received one dose of adrenaline intravenously (0.3 microgram/kg) and the other tracheally (3 micrograms/kg).

RESULTS

During the first 5 minutes after administration mean arterial pressure (MAP) and heart rate (HR) increased after both intravenous and tracheal administration (P < 0.001). The maximum increase in MAP was 28% (17-68%, median and range) after intravenous injection and 20% (6-69%, P < 0.05 when compared to intravenous injection) after tracheal instillation. In four infants, MAP increased less than 10% after tracheal instillation. The maximum increases in MAP and HR occurred 1 min (1-2 min) after intravenous injection and 3 min (2-4 min) after tracheal instillation (P < 0.001).

CONCLUSION

Tracheal administration 3 micrograms/kg adrenaline increased mean arterial blood pressure in infants with congenital cardiac anomalies, but the increase occurred later and was less consistent than after 0.3 microgram/kg of adrenaline given intravenously.

Для цитирования: Jonmarker C, Olsson A K, Jögi P, Forsell C. Hemodynamic effects of tracheal and intravenous adrenaline in infants with congenital heart anomalies.. Acta anaesthesiologica Scandinavica. 1996. DOI: 10.1111/j.1399-6576.1996.tb04562.x.