MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ajcp/aqaf008

Медицинская библиотека · American journal of clinical pathology · 2025

High-sensitivity KIT D816V variation analysis by droplet digital polymerase chain reaction: The reference laboratory perspective.

Shean Ryan C, Hellwig Sabine, Saadalla Abdulrahman, George Tracy I, Rets Anton V

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Systemic mastocytosis is a hematologic malignancy characterized by clonal expansion of neoplastic mast cells. Detection of this variation is critical for screening and diagnosis, with recent guidelines emphasizing the need for high-sensitivity assays that identify variants at a variant allele frequency below 0.05%. Our reference laboratory offers droplet digital polymerase chain reaction (ddPCR) for detection of KIT D816V at a limit of detection of 0.03% variant allele frequency-substantially higher sensitivity than next-generation sequencing (NGS).

METHODS

Because high-sensitivity KIT D816V testing is still not widely available, we present our 3-year experience with KIT D816V ddPCR in a clinical setting. From January 2021 to March 2024, KIT D816V variation was detected in 14.9% (1232/8272) of samples.

RESULTS

Peripheral blood and bone marrow positivity rates were 11.1% and 34.9%, respectively. Among 181 samples tested by both ddPCR and NGS, ddPCR identified 37.6% as positive, while NGS identified only 6.0% as positive. Next-generation sequencing showed 16% sensitivity and 100% specificity for KIT D816V detection compared with ddPCR as the gold standard, which detected the variant in 84% more samples because of its lower limit of detection. A 20-ng/mL serum tryptase threshold to screen for detecting KIT D816V by ddPCR had 73.7% sensitivity and 91.2% specificity, but lowering the serum tryptase threshold to 11.5 ng/mL increased sensitivity to 97.5%, with 70.7% specificity.

CONCLUSIONS

Overall, ddPCR for detection of KIT D816V dramatically increases sensitivity over NGS tests used for myeloid malignancies, including systemic mastocytosis. Our findings also provide support for the use of a lower serum tryptase threshold (>11.4 ng/mL instead of >20ng/mL) to initiate workup for a mast cell neoplasm.

Для цитирования: Shean Ryan C, Hellwig Sabine, Saadalla Abdulrahman, George Tracy I, Rets Anton V. High-sensitivity KIT D816V variation analysis by droplet digital polymerase chain reaction: The reference laboratory perspective.. American journal of clinical pathology. 2025. DOI: 10.1093/ajcp/aqaf008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.