MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1023/a:1008990516159

Медицинская библиотека · Journal of materials science. Materials in medicine · 1998

In vivo skeletal response and biomechanical assessment of two novel polyalkenoate cements following femoral implantation in the female New Zealand White rabbit.

Blades M C, Moore D P, Revell P A, Hill R

СтатьяПеревод в очереди

Аннотация

Glass-ionomer cements (GIC) offer several advantages over the conventional acrylic-based bone cements. The formation of an adhesive bond with bone and metals, a low setting exotherm and no systemic or local toxicity are some of the advantages cited. This study examines the in vivo biological and biomechanical behavior of two polyalkenoate cements (LG26 and LG30) implanted for 6 wk into the submetaphyseal spongiosa of the rabbit femur. Cements were implanted as both set cement rods and unset cement dough. Implantation of set rods resulted in the formation of variably mineralized osteoid/woven bone at the bone-cement interface. Mechanical (push-out) testing revealed the strength of this bone-cement interface was of similar magnitude to control (PMMA-rod implanted) animals. The bone of LG cement-dough implanted animals exhibited demineralization of pre-existing bone local to the site of implantation, accumulation of aluminum both locally and at a distance from the site of implantation, and defective mineralization of newly formed osteoid. The histological picture following LG implantation was strikingly similar to human renal osteodystrophy, in which skeletal accumulation of aluminum is a noted feature. The development of a GIC with low/no aluminum release from the unset cement dough is a priority in the further development of these cements for possible orthopaedic applications.

Для цитирования: Blades M C, Moore D P, Revell P A, Hill R. In vivo skeletal response and biomechanical assessment of two novel polyalkenoate cements following femoral implantation in the female New Zealand White rabbit.. Journal of materials science. Materials in medicine. 1998. DOI: 10.1023/a:1008990516159.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.