MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2022.10.012

Медицинская библиотека · JACC. Clinical electrophysiology · 2022

Conduction System Pacing Versus Conventional Cardiac Resynchronization Therapy in Congenital Heart Disease.

Moore Jeremy P, de Groot Natasja M S, O'Connor Matthew, Cortez Daniel, Su Jonathan, Burrows Austin, Shannon Kevin M, O'Leary Edward T, Shah Maully, Khairy Paul, Atallah Joseph, Wong Tom, Lloyd Michael S, Taverne Yannick J H J, Dubin Anne M, Nielsen Jens C, Evertz Reinder, Czosek Richard J, Madhavan Malini, Chang Philip M, Aydin Alper, Cano Óscar

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Dyssynchrony-associated left ventricular systolic dysfunction is a major contributor to heart failure in congenital heart disease (CHD). Although conventional cardiac resynchronization therapy (CRT) has shown benefit, the comparative efficacy of cardiac conduction system pacing (CSP) is unknown.

OBJECTIVES

The purpose of this study was compare the clinical outcomes of CSP vs conventional CRT in CHD with biventricular, systemic left ventricular anatomy.

METHODS

Retrospective CSP data from 7 centers were compared with propensity score-matched conventional CRT control subjects. Outcomes were lead performance, change in left ventricular ejection fraction (LVEF), and QRS duration at 12 months.

RESULTS

A total of 65 CSP cases were identified (mean age 37 ± 21 years, 46% men). The most common CHDs were tetralogy of Fallot (n = 12 [19%]) and ventricular septal defect (n = 12 [19%]). CSP was achieved after a mean of 2.5 ± 1.6 attempts per procedure (38 patients with left bundle branch pacing, 17 with HBP, 10 with left ventricular septal myocardial). Left bundle branch area pacing [LBBAP] vs HBP was associated with a smaller increase in pacing threshold (Δ pacing threshold 0.2 V vs 0.8 V; P = 0.05) and similar sensing parameters at follow-up. For 25 CSP cases and control subjects with baseline left ventricular systolic dysfunction, improvement in LVEF was non-inferior (Δ LVEF 9.0% vs 6.0%; P = 0.30; 95% confidence limits: -2.9% to 10.0%) and narrowing of QRS duration was more pronounced for CSP (Δ QRS duration 35 ms vs 14 ms; P = 0.04). Complications were similar (3 [12%] CSP, 4 [16%] conventional CRT; P = 1.00).

CONCLUSIONS

CSP can be reliably achieved in biventricular, systemic left ventricular CHD patients with similar improvement in LVEF and greater QRS narrowing for CSP vs conventional CRT at 1 year. Among CSP patients, pacing electrical parameters were superior for LBBAP vs HBP.

Для цитирования: Moore Jeremy P, de Groot Natasja M S, O'Connor Matthew, Cortez Daniel, Su Jonathan, Burrows Austin, Shannon Kevin M, O'Leary Edward T, Shah Maully, Khairy Paul, Atallah Joseph, Wong Tom, Lloyd Michael S, Taverne Yannick J H J, Dubin Anne M, Nielsen Jens C, Evertz Reinder, Czosek Richard J, Madhavan Malini, Chang Philip M, Aydin Alper, Cano Óscar. Conduction System Pacing Versus Conventional Cardiac Resynchronization Therapy in Congenital Heart Disease.. JACC. Clinical electrophysiology. 2022. DOI: 10.1016/j.jacep.2022.10.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.