IEEE transactions on bio-medical engineering · 2015

Detection of the Third Heart Sound Based on Nonlinear Signal Decomposition and Time-Frequency Localization.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Barma Shovan, Chen Bo-Wei, Ji Wen, Rho Seungmin, Chou Chih-Hung, Wang Jhing-Fa

Аннотация

This study presents a precise way to detect the third ( S3 ) heart sound, which is recognized as an important indication of heart failure, based on nonlinear single decomposition and time-frequency localization. The detection of the S3 is obscured due to its significantly low energy and frequency. Even more, the detected S3 may be misunderstood as an abnormal second heart sound with a fixed split, which was not addressed in the literature. To detect such S3, the Hilbert vibration decomposition method is applied to decompose the heart sound into a certain number of subcomponents while intactly preserving the phase information. Thus, the time information of all of the decomposed components are unchanged, which further expedites the identification and localization of any module/section of a signal properly. Next, the proposed localization step is applied to the decomposed subcomponents by using smoothed pseudo Wigner-Ville distribution followed by the reassignment method. Finally, based on the positional information, the S3 is distinguished and confirmed by measuring time delays between the S2 and S3. In total, 82 sets of cardiac cycles collected from different databases including Texas Heart Institute database are examined for evaluation of the proposed method. The result analysis shows that the proposed method can detect the S3 correctly, even when the normalized temporal energy of S3 is larger than 0.16, and the frequency of those is larger than 34 Hz. In a performance analysis, the proposed method demonstrates that the accuracy rate of S3 detection is as high as 93.9%, which is significantly higher compared with the other methods. Such findings prove the robustness of the proposed idea for detecting substantially low-energized S3 .

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты