BACKGROUND

The aim of this study was to evaluate functional outcome and complications with a long term follow up (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured locking plates.

METHODS

We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed, as well as functional evaluation using the rating scale shoulder of the University of California (UCLA), the Constant scale, score of disability of the arm, shoulder and hand (DASH) and visual analog scale (VAS). Postoperative complications, implants removal rates and new x-rays were analized.

RESULTS

The mean postoperative follow-up was 41.5 (24; 69. SD 13.4) months. Mean shoulder anterior elevation was 168.5º (120; 180. SD 22.9). The average value obtained for abduction was 175.2° (150; 180. SD 27.8), as to internal and external rotations, these were not affected. DASH 1.27% (0%; 25%. SD 4.3), UCLA 33.6 points (20; 35. SD 3.5), Constant 90.5 points (50; 100. SD 11.2) and VAS was 0 in 34 patients (83%). Complications: mild residual pain (3), hypoesthesia of the infraclavicular area (2), and rupture (1) and loosening (1) of the implant. hardware removal due to intolerance (2 cases) and new osteosynthesis due to acute implant rupture (1 case).

CONCLUSION

Our experience after a mean follow-up of 41.5 months with precontoured locking plates for the treatment of displaced mid-shaft clavicle fractures has shown good functional results, with low complication and reoperation rate.

Для цитирования: Patiño Juan Martìn, Rullan Corna Alejandro Felix, Michelini Alejandro Emilio, Abdon Ignacio, Hochbaum Sandra Denise, Wilson Fernando Zicovich. Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- ears Follow up.. The archives of bone and joint surgery. 2019.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.