Removal of central venous catheter using Evolution® Rotating Dilator.

Takamizawa Koichi, Hasumi Eriko, Fujiu Katsuhito, Inuzuka Ryo

Клинический случайСтатьяПеревод в очереди

Аннотация

We experienced the first case of a difficult-to-extract central venous catheter removed with a pacemaker lead removal system: a 14-year-old boy with Hirschsprung's disease who had repeated catheter infections that could not be removed by traction. Because the catheter lumen was occluded, a suture was tied around the end of the catheter and the catheter was removed with a rotating dilator.

Для цитирования: Takamizawa Koichi, Hasumi Eriko, Fujiu Katsuhito, Inuzuka Ryo. Removal of central venous catheter using Evolution® Rotating Dilator.. Cardiology in the young. 2024. DOI: 10.1017/s1047951124000209.