MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1752-7163/ad7a20

Медицинская библиотека · Journal of breath research · 2024

Rapid point-of-care breath test predicts breast cancer and abnormal mammograms in symptomatic women.

Phillips Michael, Bevers Therese B, Larsen Linda Hovanessian, Pappas Nadine, Pathak Sonali

СтатьяПеревод в очереди

Аннотация

Previous studies have reported volatile organic compounds (VOCs) in the breath as biomarkers of breast cancer. These biomarkers may be derived from cancer-associated fibroblasts, in which oxidative stress degrades polyunsaturated fatty acids to volatile alkanes and methylated alkane derivatives that are excreted in the breath. We evaluated a rapid point-of-care test for breath VOC biomarkers as predictors of breast cancer and abnormal mammograms. We studied 593 women aged⩾18 yr referred to three sites for mammography for a symptomatic breast-related concern (e.g. breast mass, nipple discharge). A rapid point-of-care breath testing system collected and concentrated alveolar breath VOCs on a sorbent trap and analyzed them with gas chromatography and surface acoustic wave detection in <6 min. Breath VOC chromatograms were randomly assigned to a training set or to a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer and abnormal mammograms in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set.Prediction of breast cancer:50 women had biopsy-proven breast cancer (invasive cancer 41, ductal non-invasive cancer 9)Unsplit data set:breath VOCs identified breast cancer with 83% accuracy (area under curve of receiver operating characteristic), 82% sensitivity and 77.1% specificity.Split data sets:training set breath VOCs identified breast cancer with 80.3% accuracy, 84% sensitivity and 74.3% specificity. Corresponding values in the validation set were 68%% accuracy, 72.4% sensitivity and 61.5% specificity.Prediction of BIRADS 4 and 5 mammograms (versus BIRADS 1, 2 and 3): unsplit data set:breath VOCs identified abnormal mammograms with 76.2% accuracy.Split data sets:breath VOCs identified abnormal mammograms with 74.2% accuracy, 73.3% sensitivity and 60% specificity. Corresponding values in the validation set were 60.5% accuracy, 64.2% sensitivity and 51% specificity. A rapid point-of-care test for breath VOC biomarkers predicted risk of breast cancer and abnormal mammograms in women with breast-related symptoms.

Для цитирования: Phillips Michael, Bevers Therese B, Larsen Linda Hovanessian, Pappas Nadine, Pathak Sonali. Rapid point-of-care breath test predicts breast cancer and abnormal mammograms in symptomatic women.. Journal of breath research. 2024. DOI: 10.1088/1752-7163/ad7a20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.