Evaluating Normal Saline Locking With Totally Implanted Vascular Access Devices for Patients on 90-Day Maintenance Flushing.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Ramsey Krystal, Collins Jessika Ann, Toedte Brooke
Аннотация
BACKGROUND: Heparin has been the preferred locking solution for many organizations for totally implanted vascular access devices (TIVADs). Published data are limited on the use of normal saline alone as a locking solution for TIVAD 90-day maintenance flushing.
OBJECTIVES: The purpose of this evidence-based practice initiative was to determine whether locking TIVADs with normal saline alone during a 90-day maintenance flushing protocol resulted in an increase in partial occlusions.
METHODS: A clinical team monitored alteplase administration to measure partial occlusions. Prior to heparin deimplementation, nurses maintained TIVADs using 500 units of heparin upon de-access. Infusion nurses received education about published data, pulsatile flushing, and clamping sequences prior to device deimplementation.
FINDINGS: Encounters (N = 2,908) during six months of heparin locking were compared to encounters (N = 3,239) during six months of normal saline locking. Data demonstrated minimal variance between locking with normal saline compared to heparin.
OBJECTIVES: The purpose of this evidence-based practice initiative was to determine whether locking TIVADs with normal saline alone during a 90-day maintenance flushing protocol resulted in an increase in partial occlusions.
METHODS: A clinical team monitored alteplase administration to measure partial occlusions. Prior to heparin deimplementation, nurses maintained TIVADs using 500 units of heparin upon de-access. Infusion nurses received education about published data, pulsatile flushing, and clamping sequences prior to device deimplementation.
FINDINGS: Encounters (N = 2,908) during six months of heparin locking were compared to encounters (N = 3,239) during six months of normal saline locking. Data demonstrated minimal variance between locking with normal saline compared to heparin.