MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.diagmicrobio.2016.07.027

Медицинская библиотека · Diagnostic microbiology and infectious disease · 2016

Identification of mycobacterium spp. and nocardia spp. from solid and liquid cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS).

Girard Victoria, Mailler Sandrine, Welker Martin, Arsac Maud, Cellière Béatrice, Cotte-Pattat Pierre-Jean, Chatellier Sonia, Durand Géraldine, Béni Anne-Marie, Schrenzel Jacques, Miller Elizabeth, Dussoulier Rahima, Dunne W Michael, Butler-Wu Susan, Saubolle Michael A, Sussland Den, Bell Melissa, van Belkum Alex, Deol Parampal

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Identification of microorganisms by MALDI-TOF MS has been widely accepted in clinical microbiology. However, for Mycobacterium spp. and Nocardia spp. such identification has not yet reached the optimal level of routine testing. Here we describe the development of an identification tool for 49 and 15 species of Mycobacterium spp. and Nocardia spp., respectively. During database construction, a number of ambiguous reference identifications were revealed and corrected via molecular analyses. Eventually, more than 2000 individual mass spectra acquired from 494 strains were included in a reference database and subjected to bio-statistical analyses. This led to correct species identification and correct combination of species into several complexes or groups, such as the Mycobacterium tuberculosis complex. With the Advanced Spectrum Classifier algorithm, class-specific bin weights were determined and tested by cross-validation experiments with good results. When challenged with independent isolates, overall identification performance was 90% for identification of Mycobacterium spp. and 88% for Nocardia spp. However, for a number of Mycobacterium sp. isolates, no identification could be achieved and in most cases, this could be attributed to the production of polymers that masked the species-specific protein peak patterns. For the species where >20 isolates were tested, correct identification reached 95% or higher. With the current spectral database, the identification of Mycobacterium spp. and Nocardia spp. by MALDI-TOF MS can be performed in routine clinical diagnostics although in some complicated cases verification by sequencing remains mandatory.

Для цитирования: Girard Victoria, Mailler Sandrine, Welker Martin, Arsac Maud, Cellière Béatrice, Cotte-Pattat Pierre-Jean, Chatellier Sonia, Durand Géraldine, Béni Anne-Marie, Schrenzel Jacques, Miller Elizabeth, Dussoulier Rahima, Dunne W Michael, Butler-Wu Susan, Saubolle Michael A, Sussland Den, Bell Melissa, van Belkum Alex, Deol Parampal. Identification of mycobacterium spp. and nocardia spp. from solid and liquid cultures by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS).. Diagnostic microbiology and infectious disease. 2016. DOI: 10.1016/j.diagmicrobio.2016.07.027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.