MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc · 1996

Effect of 12 atmospheres helium-oxygen on the response of mice to convulsant drugs.

Syapin P J, Jones B L, Finn D A, Davies D L, Alkana R L

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

The mechanism by which 12 atm abs of a helium-oxygen gas mixture (heliox) antagonizes behavioral effects of ethanol is unknown. Although the threshold for pressure-reversal of general anesthesia and expression of the high pressure neurologic syndrome (HPNS) is well above 12 atm abs in mice, the ethanol antagonism by 12 atm abs heliox could result from similar underlying excitatory effects. To investigate this possibility, the behavior of water-injected control mice and the latency to convulsions in drug-injected mice were determined in 1 atm abs air and 12 atm abs heliox. Four convulsant drugs were tested: picrotoxin (2 mg/kg), dl-allylglycine (300 mg/kg), isoniazid (300 mg/kg), and l-methionine-dl-sulfoximine (170 mg/kg). Responses were videotaped to observe behavior and to measure latency to the onset of myoclonus and clonus. Results indicated no observable excitatory effects of 12 atm abs in control mice. The latency to myoclonus was significantly reduced by pressure in allylglycine-treated mice but not in mice treated with the other convulsants. Latency to clonus was not significantly altered by pressure, relative to latency at 1 atm abs heliox, for any drug tested. In conclusion, the present findings indicate that exposure to 12 atm abs heliox is not proconvulsant and, thus, the findings do not support the hypothesis that 12 atm abs heliox antagonizes ethanol indirectly via an increase in central nervous system excitability.

Для цитирования: Syapin P J, Jones B L, Finn D A, Davies D L, Alkana R L. Effect of 12 atmospheres helium-oxygen on the response of mice to convulsant drugs.. Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc. 1996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.