Covered stents for implantation into the right ventricular outflow tract in infants with tetralogy of Fallot/pulmonary atresia with ventricular septal defect.

Surmacz Rafał, Vodiskar Janez, Tanase Daniel, Georgiev Stanimir, Sigler Matthias, Ewert Peter, Hörer Jürgen, Eicken Andreas, Gendera Katarzyna Karolina

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Right ventricular outflow tract stenting is a palliative treatment option in symptomatic infants with tetralogy of Fallot or with pulmonary atresia with ventricular septal defect. Predominantly bare metal stents are used for this procedure. The authors sought to assess the efficacy and safety of using the covered coronary stent grafts for the right ventricular outflow tract stenting.

METHODS

Between November 2017 and July 2021, the covered coronary stent graft was used to widen the right ventricular outflow tract in 20 symptomatic patients (pulmonary atresia with ventricular septal defect n = 5, tetralogy of Fallot n = 15).

RESULTS

All stent grafts were implanted successfully. The median time of palliation was 156 (43-1578) days. Eleven patients required stent redilation. Fifteen patients required additional stent implantation to relieve a proximal obstruction in the right ventricular outflow tract. There were three complications observed: right ventricular outflow tract perforation (n = 1), stent embolisation (n = 1), and main pulmonary aneurysm (n = 1). Oxygen saturation improved immediately after the procedure. During the follow-up time, all stents were patent, and we observed a significant increase in the diameters of the pulmonary arteries. Sixteen patients had corrective surgery performed with complete and easy removal of the implanted stents.

CONCLUSIONS

Stenting of the right ventricular outflow tract with stent grafts was safe and effective and provided a durable method of palliation. Utilisation of the covered coronary stent graft facilitated surgical removal of the implanted stent during the surgical correction.

Для цитирования: Surmacz Rafał, Vodiskar Janez, Tanase Daniel, Georgiev Stanimir, Sigler Matthias, Ewert Peter, Hörer Jürgen, Eicken Andreas, Gendera Katarzyna Karolina. Covered stents for implantation into the right ventricular outflow tract in infants with tetralogy of Fallot/pulmonary atresia with ventricular septal defect.. Cardiology in the young. 2025. DOI: 10.1017/s1047951125109359.