MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2014.02.012

Медицинская библиотека · European journal of radiology · 2014

Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging.

Kinner Sonja, Steinweg Verena, Maderwald Stefan, Radtke Arnold, Sotiropoulos Georgios, Forsting Michael, Schroeder Tobias

Контролируемое клиническое исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC).

MATERIALS AND

METHODS

30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w±IR) were acquired 20-30min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann-Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated.

RESULTS

All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference.

CONCLUSIONS

Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR.

Для цитирования: Kinner Sonja, Steinweg Verena, Maderwald Stefan, Radtke Arnold, Sotiropoulos Georgios, Forsting Michael, Schroeder Tobias. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging.. European journal of radiology. 2014. DOI: 10.1016/j.ejrad.2014.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.