MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijporl.2017.10.030

Медицинская библиотека · International journal of pediatric otorhinolaryngology · 2017

Low rate of positive bronchoscopy for suspected foreign body aspiration in infants.

Sheehan Cameron C, Lopez Joseph, Elmaraghy Charles A

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To describe our institution's low rate of positive bronchoscopy in infants suspected of inhaling a foreign body.

STUDY

DESIGN

Retrospective chart review.

METHODS

A retrospective review was performed of patients at a tertiary children's hospital with suspected inhalation of a foreign body. Charts were reviewed for demographic information, radiologic findings, operative reports, and respiratory viral panels were reviewed.

RESULTS

Sixteen pediatric patients under 12 months of age were identified from 2008 to 2016 with a diagnosis of possible airway foreign body inhalation who underwent emergent bronchoscopy. Of these patients, only one was positive for a foreign body present in the airway. The remaining 15 children were found to have a negative direct laryngoscopy and bronchoscopy evaluation for a foreign body. Of these fifteen patients, 14 were found to have structural airway abnormalities and 7 tested positive for a respiratory viral infection.

CONCLUSIONS

Our institution has a low rate of positive bronchoscopy for highly suspected foreign body inhalation in a group of patients less than 12 months of age. Patients presenting with respiratory distress, stridor, or other airway symptoms were often found to have an underlying airway abnormality or viral infection, which coupled with an unclear history, would increase the suspicion for an airway foreign body and subsequent decision to perform bronchoscopy. In stable patients, diagnostic evaluation for an underlying respiratory infection should be performed in these cases.

LEVEL OF EVIDENCE: Case Series.

Для цитирования: Sheehan Cameron C, Lopez Joseph, Elmaraghy Charles A. Low rate of positive bronchoscopy for suspected foreign body aspiration in infants.. International journal of pediatric otorhinolaryngology. 2017. DOI: 10.1016/j.ijporl.2017.10.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.