INTRODUCTION

Dilute Russell's viper venom time (dRVVT) and activated partial thromboplastin time (APTT) are the mainstay assays in lupus anticoagulant (LA) detection yet they have limitations, particularly in relation to interferences and specificity. The recently validated Taipan snake venom time (TSVT) screening with ecarin time (ET) confirmatory assays overcome many of those limitations due to the innate specificity engendered from direct prothrombin activation, and insensitivity to the effects of vitamin K antagonists (VKA). The present study aimed to further evidence diagnostic utility of TSVT/ET by performing them in samples from 116 nonanticoagulated patients with established triple-positive antiphospholipid syndrome (APS).

METHODS

Samples were identified in three expert centres who performed dRVVT, APTT and solid phase antiphospholipid antibody assays with reagents from a variety of manufacturers. All samples additionally received TSVT/ET analysis using standardised reagents.

RESULTS

Ninety seven of 116 (83.6%) were dRVVT- and APTT-positive, 85/97 (87.6%) of which were TSVT/ET-positive, 9/116 (7.8%) were dRVVT-positive only, 6 of which were TSVT/ET-positive, and 10/116 (8.6%) were APTT-positive only, 5 of which were TSVT/ET-positive. 96/116 TSVT/ET-positivity returned a high sensitivity for LA of 82.8%. Low coefficients of determination revealed weak relationships between LA potency and anticardiolipin and anti-β2-glycoprotein I antibody titres for all three LA assays.

CONCLUSIONS

TSVT/ET has high sensitivity for the clinically significant LA found in triple positive APS patients. TSVT/ET can establish multiple LA assay positivity in nonanticoagulated patients negative for one of dRVVT or APTT, and is the only assay pairing insensitive to VKAs, the recommended anticoagulation for APS.

Для цитирования: Moore Gary W, Platton Sean, Yartey Nada, Foxton Eleanor, White Danielle, MacDonald Stephen G. Taipan snake venom time has high sensitivity for lupus anticoagulants in non-anticoagulated, triple positive antiphospholipid syndrome patients.. International journal of laboratory hematology. 2024. DOI: 10.1111/ijlh.14240.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.