Аннотация

PURPOSE: To compare plate positioning in clinical practice of 2 commonly used volar locking plate designs with respect to the watershed line as classified by the Soong grading system.

METHODS

For this retrospective study, we included a total of 400 patients who underwent open reduction and internal fixation between May 2013 and February 2018. Cohort 1 was defined as patients treated with distal volar radius (DVR) plates during this period. Cohort 2 comprised 200 patients who had volar plate fixation with variable angle locking compression plates (LCP) during the same period. Standardized lateral wrist radiographs were categorized into Soong grade 0, 1, or 2.

RESULTS

In cohort 1, 87 plates (43.5%) were not prominent volar to the watershed line, grade 0; 95 plates (47.5%) demonstrated grade 1 prominence; and 18 plates (9.0%) demonstrated grade 2 prominence. In cohort 2, 63 plates (31.5%) were grade 0; 103 plates (51.5%) were grade 1; and 34 plates (17%) had grade 2 prominence on, and volar to, the watershed line. These radiographic results show a greater incidence of volar plate prominence with respect to the watershed line, as defined as Soong grading, in cohort 2.

CONCLUSION

This study shows that the use of the variable angle LCP plate is associated with more prominent volar positioning with respect to the watershed line compared with the DVR plate.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic II.

Для цитирования: Bergsma Minke, Brown Kimberly, Doornberg Job, Sierevelt Inger, Jaarsma Ruurd, Jadav Bhavin. Distal Radius Volar Plate Design and Volar Prominence to the Watershed Line in Clinical Practice: Comparison of Soong Grading of 2 Common Plates in 400 Patients.. The Journal of hand surgery. 2019. DOI: 10.1016/j.jhsa.2019.04.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.