Аннотация

Extensor mechanism disruptions are relatively uncommon knee injuries. Within this group, delayed treatment is an infrequent but difficult clinical situation. Fibrous degeneration, muscle contraction and subsequent hiatus present a challenge to the orthopaedic surgeon. We present an unusual case of a successful delayed repair using the Mitek anchors system (Mitek Products Inc., a division of Ethicon Inc., Westwood, Massachusetts).

Для цитирования: Kerin C, Hopgood P, Banks A J. Delayed repair of the quadriceps using the Mitek anchor system: a case report and review of the literature.. The Knee. 2006. DOI: 10.1016/j.knee.2005.11.004.