MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/archdischild-2019-317066

Медицинская библиотека · Archives of disease in childhood. Fetal and neonatal edition · 2019

Diagnostic values of the femoral pulse palpation test.

Khammari Nystrom Fatine, Petersson Gunnar, Stephansson Olof, Johansson Stefan, Altman Maria

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To calculate diagnostic values of the femoral pulse palpation to detect coarctation of the aorta or other left-sided obstructive heart anomalies in newborn infants.

DESIGN

Population-based cohort study.

SETTING

Stockholm-Gotland County 2008-2012.

PATIENTS: All singleton live-born infants without chromosomal trisomies, at ≥35 gestational weeks, followed-up until 1-2 years of age.

MAIN OUTCOME MEASURES: Diagnostic values and ORs for the femoral pulse test and subsequent diagnosis of coarctation of the aorta or left-sided obstructive heart malformation.

RESULTS

Among the 118 592 included infants, 432 had weak or absent femoral pulses at the newborn examination. Seventy-eight infants were diagnosed with coarcation of the aorta and 48 with other left-sided obstructive heart malformations. The diagnostic values for the femoral pulse palpation test to detect coarctation of the aorta were: sensitivity: 19.2%, specificity: 99.6, positive predictive value: 3.5% and negative predictive value: 99.9%. For left-sided heart malformations: sensitivity: 8.3%, specificity: 99.6%, positive predictive value: 0.9% and negative predictive value: 100%. Sensitivity for coarctation of the aorta increased from 16.7% when examined at <12 hours of age to 30.0% at ≥96 hours of age.

CONCLUSIONS

The femoral pulse test to detect coarctation of the aorta and left-sided heart malformations has limited sensitivity, whereas specificity is high. As many infants with life-threatening cardiac malformations leave the maternity ward undiagnosed, further efforts are necessary to improve the diagnostic yield of the routine newborn examination.

Для цитирования: Khammari Nystrom Fatine, Petersson Gunnar, Stephansson Olof, Johansson Stefan, Altman Maria. Diagnostic values of the femoral pulse palpation test.. Archives of disease in childhood. Fetal and neonatal edition. 2019. DOI: 10.1136/archdischild-2019-317066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.