MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.177.5.1771199

Медицинская библиотека · AJR. American journal of roentgenology · 2001

Radiologic differentiation of intraocular glass: evaluation of imaging techniques, glass types, size, and effect of intraocular hemorrhage.

Gor D M, Kirsch C F, Leen J, Turbin R, Von Hagen S

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The accurate detection of intraocular foreign bodies is critically important in treating ocular trauma. The purpose of this study was to evaluate the efficacy of CT, MR imaging, and sonography in detecting seven types of glass varying in size and placed in three locations in the globe, and to examine the effect of intraocular hemorrhage.

MATERIALS AND

METHODS

Glass pieces were cut into 1.5-, 1.0-, and 0.5-mm pieces and implanted on the corneal surface and the anterior and posterior chambers of 42 fresh porcine eyes. Twenty-one eyes were scanned comparing axial CT, helical CT, and MR imaging. The remaining 21 eyes were scanned using helical CT and sonography after implantation in a simulated human skull before and after placement of blood in the anterior chamber (hyphema).

RESULTS

Detection rates were 57.1% for helical CT, 41.3% for axial CT, and 11.1% for T1-weighted MR imaging (n = 63 fragments). Results were significant (p < 0.0001). Sonography detected 43% of glass fragments in the posterior chamber and 24% in the anterior chamber. Detectability was greatest for green beer bottle glass (90.3%) and least for spectacle glass (43.1%) (p < 0.0001). Detection rates for size ranged from 96.2% at 1.5 mm to 48.3% at 0.5 mm, which was also significant (p < 0.0001). On helical CT, anterior chamber glass was easiest to detect (91.7%) and corneal surface glass the most difficult (64.9%). Hyphema made no statistical difference (p < 0.0001).

CONCLUSION

Helical CT was the most sensitive imaging modality for the detection of intraocular glass. The sensitivity of detection was unaffected by hyphema but was determined by the type of glass, size, and location.

Для цитирования: Gor D M, Kirsch C F, Leen J, Turbin R, Von Hagen S. Radiologic differentiation of intraocular glass: evaluation of imaging techniques, glass types, size, and effect of intraocular hemorrhage.. AJR. American journal of roentgenology. 2001. DOI: 10.2214/ajr.177.5.1771199.