MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.70885

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026

The Performance of High Tip Load Polymer Jacket Guidewires in Chronic Total Occlusion Revascularization.

Gurbuz Ahmet Seyfeddin, Ozturk Semi, Sural Sefa, Tanboga Halil Ibrahim, Aslan Vedat, Gorgulu Sevket

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Guidewire selection influences chronic total occlusion (CTO) percutaneous coronary intervention (PCI) success. High-tip-load (>1.5 g) polymer-jacketed guidewires (PJWs) combine penetration capability and lubricity, but comparative data versus non-polymer-jacketed penetration wires are limited.

AIMS: To compare procedural outcomes between high-tip-load PJWs and non-PJW penetration guidewires in CTO PCI.

METHODS

We retrospectively analyzed 1,850 consecutive CTO PCI procedures performed between January 2020 and June 2025. The analytical cohort comprised 220 PJW and 642 non-PJW procedures. Inverse probability of treatment weighting (IPTW) adjusted for 39 covariates; a propensity-score-matched sensitivity analysis yielded 208 pairs.

RESULTS

After IPTW adjustment, PJW use was associated with higher antegrade recanalization (OR 1.79, 95% CI 1.06-3.02; p = 0.028), whereas procedural success was not significantly different (OR 2.10, 95% CI 0.97-4.52; p = 0.059). Procedure time and air kerma were lower with PJWs. Unadjusted perforation rates did not differ (4.1% vs 5.1%; OR 0.79, 95% CI 0.37-1.67; p = 0.530), whereas the matched analysis suggested fewer perforations with PJWs (3.4% vs 8.2%; OR 0.39, 95% CI 0.16-0.97; p = 0.042). Because only 24 matched events occurred, this safety finding should be considered hypothesis-generating. In-hospital major adverse cardiac events did not differ (p = 0.954).

CONCLUSION

High-tip-load PJWs achieved comparable procedural success, higher antegrade recanalization, improved procedural efficiency, and a potential matched-cohort safety signal. They may be considered before escalation to high-force penetration wires.

Для цитирования: Gurbuz Ahmet Seyfeddin, Ozturk Semi, Sural Sefa, Tanboga Halil Ibrahim, Aslan Vedat, Gorgulu Sevket. The Performance of High Tip Load Polymer Jacket Guidewires in Chronic Total Occlusion Revascularization.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2026. DOI: 10.1002/ccd.70885.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.