MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/wjs.12203

Медицинская библиотека · World journal of surgery · 2024

Femoral arterial cannulation for surgical repair of stanford type A aortic dissection.

Juvonen Tatu, Vendramin Igor, Mariscalco Giovanni, Jormalainen Mikko, Perrotti Andrea, Hervé Amélie, Mazzaro Enzo, Gatti Giuseppe, Pettinari Matteo, Peterss Sven, Buech Joscha, Nappi Francesco, Pinto Angel G, Rodriguez Lega Javier, Pol Marek, Rocek Jan, Kacer Petr, Rukosujew Andreas, Wisniewski Konrad, Piani Daniela, Demal Till, Conradi Lenard, Ferrante Luisa, Rinaldi Mauro, Quintana Eduard, Pruna-Guillen Robert, Gerelli Sebastien, Di Perna Dario, Fiore Antonio, Folliguet Thierry, Acharya Metesh, El-Dean Zein, Field Mark, Kuduvalli Manoj, Onorati Francesco, Francica Alessandra, Mäkikallio Timo, Dell'Aquila Angelo M, Mustonen Caius, Raivio Peter, Rosato Stefano, Biancari Fausto

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The benefits and harms associated with femoral artery cannulation over other sites of arterial cannulation for surgical repair of acute Stanford type A aortic dissection (TAAD) are not conclusively established.

METHODS

We evaluated the outcomes after surgery for TAAD using femoral artery cannulation, supra-aortic arterial cannulation (i.e., innominate/subclavian/axillary artery cannulation), and direct aortic cannulation.

RESULTS

3751 (96.1%) patients were eligible for this analysis. In-hospital mortality using supra-aortic arterial cannulation was comparable to femoral artery cannulation (17.8% vs. 18.4%; adjusted OR 0.846, 95% CI 0.799-1.202). This finding was confirmed in 1028 propensity score-matched pairs of patients with supra-aortic arterial cannulation or femoral artery cannulation (17.5% vs. 17.0%, p = 0.770). In-hospital mortality after direct aortic cannulation was lower compared to femoral artery cannulation (14.0% vs. 18.4%, adjusted OR 0.703, 95% CI 0.529-0.934). Among 583 propensity score-matched pairs of patients, direct aortic cannulation was associated with lower rates of in-hospital mortality (13.4% vs. 19.6%, p = 0.004) compared to femoral artery cannulation. Switching of the primary site of arterial cannulation was associated with increased rate of in-hospital mortality (36.5% vs. 17.0%; adjusted OR 2.730, 95% CI 1.564-4.765). Ten-year mortality was similar in the study cohorts.

CONCLUSIONS

In this study, the outcomes of surgery for TAAD using femoral arterial cannulation were comparable to those using supra-aortic arterial cannulation. However, femoral arterial cannulation was associated with higher in-hospital mortality than direct aortic cannulation.

TRIAL REGISTRATION: ClinicalTrials.gov registration code: NCT04831073.

Для цитирования: Juvonen Tatu, Vendramin Igor, Mariscalco Giovanni, Jormalainen Mikko, Perrotti Andrea, Hervé Amélie, Mazzaro Enzo, Gatti Giuseppe, Pettinari Matteo, Peterss Sven, Buech Joscha, Nappi Francesco, Pinto Angel G, Rodriguez Lega Javier, Pol Marek, Rocek Jan, Kacer Petr, Rukosujew Andreas, Wisniewski Konrad, Piani Daniela, Demal Till, Conradi Lenard, Ferrante Luisa, Rinaldi Mauro, Quintana Eduard, Pruna-Guillen Robert, Gerelli Sebastien, Di Perna Dario, Fiore Antonio, Folliguet Thierry, Acharya Metesh, El-Dean Zein, Field Mark, Kuduvalli Manoj, Onorati Francesco, Francica Alessandra, Mäkikallio Timo, Dell'Aquila Angelo M, Mustonen Caius, Raivio Peter, Rosato Stefano, Biancari Fausto. Femoral arterial cannulation for surgical repair of stanford type A aortic dissection.. World journal of surgery. 2024. DOI: 10.1002/wjs.12203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.