DOI 10.1016/s0002-9378(99)70322-4
Utility of minor ultrasonographic markers in the prediction of abnormal fetal karyotype at a prenatal diagnostic center.
Аннотация
OBJECTIVE
This study was undertaken to assess the value of minor ultrasonographic markers in predicting significant karyotypic abnormalities.
STUDY
DESIGN
A total of 2743 fetuses (14-24 weeks' gestation) prospectively underwent a detailed ultrasonographic survey before genetic amniocentesis. Criteria for 8 minor ultrasonographic markers were established. Odds ratios for significant karyotypic abnormalities in the presence of minor ultrasonographic markers were calculated with the chi(2) and Fisher exact tests.
RESULTS
Of the fetuses, 14.6% had a single minor ultrasonographic marker, 2.1% had >/=2 minor ultrasonographic markers, and 2.7% had >/=1 major ultrasonographic abnormality. One hundred four fetuses (3.8%) had an abnormal karyotype. Compared with a normal ultrasonographic examination result a single minor ultrasonographic marker increased the risk of karyotypic abnormality 5.7-fold (95% confidence interval, 3.5-9.3), whereas multiple minor markers increased the risk of an abnormal karyotype 12-fold (95% confidence interval, 5.5-26.5). When they were identified ultrasonographically in isolation, echogenic bowel, 2-vessel umbilical cord, echogenic intracardiac foci, choroidal separation, and choroid plexus cysts were statistically associated with an abnormal karyotype. When minor markers were identified in clusters of >/=2, echogenic bowel, short femur, 2-vessel umbilical cord, echogenic intracardiac foci, and mild ventriculomegaly were significantly predictive of karyotypic abnormality. With respect to the a priori aneuploidy risk of 1:26 and the a priori Down syndrome risk of 1:50, a normal ultrasonographic examination result reduced the risks to 1:67 and 1:120, respectively. The use of minor ultrasonographic markers in addition to major ultrasonographic abnormalities increased the detection of karyotypic abnormality from 27.9% to 68.3%. For trisomy 21 the sensitivity rose from 16.4% to 67. 3%.
CONCLUSIONS
Significant karyotypic abnormality risk assessment by ultrasonography was greatly enhanced by the addition of minor ultrasonographic markers. Further, clusters of minor ultrasonographic markers greatly increased the likelihood of karyotypic abnormality compared with a single minor marker. A completely normal ultrasonographic examination result reduced the risk of an abnormal karyotype by 62%. Inclusion of minor ultrasonographic markers in the genetic sonogram in a high-risk population will allow the detection of 68% of fetuses with karyotypic abnormalities with a false-positive rate of 17%.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.