MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5837/bjc.2026.030

Медицинская библиотека · The British journal of cardiology · 2026

Transitioning into the new era of conduction system pacing (CSP): a district general hospital experience.

Salisbury Thomas, Appalanaidu Nageswary, Coe Calvin, Kuhar Hitesh, Haynes Zoe, Nelson Thomas, Sheridan Paul, Lee Deacon

СтатьяПеревод в очереди

Аннотация

Conduction system pacing (CSP) - encompassing His-bundle pacing (HBP) and left bundle-branch area pacing (LBBAP) - delivers more physiological ventricular pacing compared with traditional right ventricular (RV) pacing. It is gaining traction beyond tertiary centres, however, evidence from district general hospitals (DGHs) remains limited. We aimed to evaluate the feasibility, electrical performance, and early clinical outcomes of CSP implemented in a UK DGH. We performed a retrospective single-centre study of consecutive patients who underwent successful CSP at Chesterfield Royal Hospital. HBP implants (n=20) were performed between June 2019 and August 2022; LBBAP implants (n=71) between January 2023 and May 2025. Baseline demographics, procedural metrics, pacing parameters, complications, heart-failure (HF) readmissions, and echocardiographic data to 12 months were obtained from electronic records. Ninety-one patients (mean age 76 ± 10 years; 69% male) received CSP, most commonly for left ventricular systolic dysfunction (LVSD) (40%) or anticipated high right-ventricular pacing burden (42%). LBBAP demonstrated lower implant thresholds than HBP (0.92 ± 0.44 V vs. 1.50 ± 0.77 V) and remained stable to 12 months (0.68 ± 0.25 V). HBP thresholds rose to 2.11 ± 1.49 V at 12 months. Screening time was shorter with LBBAP (9.6 ± 5.9 min) than HBP (14.4 ± 6.8 min, p<0.01). No infections or septal haematomas occurred. Lead revision was required in two HBP recipients and none with LBBAP (hazard ratio 17.14, p=0.067). Nine patients (9.9%) were readmitted with HF, occurring between 56 and 1,500 days post-implant. In conclusion, CSP can be implemented safely and effectively in a DGH setting. LBBAP offers superior electrical stability, shorter procedure time, and less lead revisions, supporting its preferential adoption as the default pacing strategy for CSP.

Для цитирования: Salisbury Thomas, Appalanaidu Nageswary, Coe Calvin, Kuhar Hitesh, Haynes Zoe, Nelson Thomas, Sheridan Paul, Lee Deacon. Transitioning into the new era of conduction system pacing (CSP): a district general hospital experience.. The British journal of cardiology. 2026. DOI: 10.5837/bjc.2026.030.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.