DOI 10.1016/s0741-5214(96)70202-1

Медицинская библиотека · Journal of vascular surgery · 1996

Axillary grafts for difficult hemodialysis access.

McCann R L

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study describes the largest reported experience to date with axillary artery-to-axillary vein or axillary artery-to-jugular vein polytetrafluoroethylene bridge fistulas for hemodialysis access. The purpose of the study was to determine the incidence of complications and the durability of the access to better determine the role of this procedure in the dialysis access algorithm.

METHODS

A single center's experience over a period of 5 years was retrospectively reviewed.

RESULTS

Twenty-six axillary grafts were placed in 24 patients. All but one were used for dialysis. At the time of access creation, the patients had been undergoing dialysis for a mean of 77 months (range, 5 to 256 months), had had a mean of 9.4 previous access procedures, and had exhausted all arm sites. The life-table patency rate at 3 years was 60%. The incidence of infection and thrombosis were comparable with conventional arm bridge fistulas. Neither vascular steal phenomenon nor neurologic injury occurred in this series.

CONCLUSIONS

Axillary artery-to-axillary vein or axillary artery-to-jugular vein polytetrafluoroethylene bridge fistula is an excellent and durable secondary access strategy. We recommend that it be used after exhaustion of conventional arm sites.

Для цитирования: McCann R L. Axillary grafts for difficult hemodialysis access.. Journal of vascular surgery. 1996. DOI: 10.1016/s0741-5214(96)70202-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.