MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/jamaophthalmol.2018.3931

Медицинская библиотека · JAMA ophthalmology · 2018

Association of Cadmium and Lead Exposure With the Incidence of Contrast Sensitivity Impairment Among Middle-aged Adults.

Paulsen Adam J, Schubert Carla R, Johnson Lauren J, Chen Yanjun, Dalton Dayna S, Klein Barbara E K, Klein Ronald, Pinto Alex, Cruickshanks Karen J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

IMPORTANCE

Contrast sensitivity (CS) is an important indicator of visual function that affects daily life, including mobility, visually intensive tasks, safety, and autonomy. Understanding the risk factors for CS impairment could prevent decreases in visual function.

OBJECTIVE

To determine the incidence of and factors associated with CS impairment in a large cohort.

DESIGN, SETTING, AND

PARTICIPANTS

The Beaver Dam Offspring Study is an ongoing longitudinal cohort study of aging involving adults in Beaver Dam, Wisconsin. Participants who were free of CS impairment in both eyes at baseline were included (N = 1983). Baseline data collection occurred from June 8, 2005, through August 4, 2008, when the participants ranged from 21 to 84 years of age. Two follow-up examinations occurred at 5-year intervals: one was conducted between July 12, 2010, and March 21, 2013, and the other between July 1, 2015, and November 13, 2017. Data analysis was performed from November 27, 2017, to February 27, 2018.

MAIN OUTCOMES AND MEASURES: Contrast sensitivity testing was conducted with Pelli-Robson letter sensitivity charts, and incident impairment was defined as a log CS score less than 1.55 in either eye at any follow-up examination. Cadmium and lead levels were measured in whole blood with inductively coupled plasma mass spectrometry. Associations between baseline characteristics and CS impairment incidence were examined using Cox proportional hazard models and quantified as hazard ratios (HRs) with 95% CI.

RESULTS

Of the 1983 participants included, 1028 (51.8%) were female and 955 (48.2%) were male, with a mean (SD) age of 48 (9.3) years. The 10-year cumulative incidence of CS impairment was 24.8% (95% CI, 22.9-26.8), similar in women (24.9%) and men (24.6%), and highest in the oldest age group (65-84 years) at 66.3%. In multivariable models, cadmium level in the highest quintile (HR, 1.35; 95% CI, 1.02-1.78), older age (HR, 1.36; 95% CI, 1.25-1.47), larger waist circumference (HR, 1.06; 95% CI, 1.01-1.11), and more plaque sites (1-3 sites: HR, 1.43; 95% CI, 1.07-1.92; 4-6 sites: HR, 2.75; 95% CI, 1.26-6.05) were among the factors associated with increased risk, while male sex (HR, 0.77; 95% CI, 0.60-0.98) and any alcohol consumption (HR, 0.61; 95% CI, 0.43-0.88) were associated with decreased risk. Results were similar when smoking status replaced cadmium exposure in the models. Lead level was not associated with increased risk.

CONCLUSIONS AND RELEVANCE: This study's findings suggest that incident CS impairment was common in the 10-year follow-up, with cadmium, but not lead, exposure associated with increased risk. The associations of diminished CS with other modifiable risk factors found appear to imply that changes in behavior may reduce future incidence of CS impairment.

Для цитирования: Paulsen Adam J, Schubert Carla R, Johnson Lauren J, Chen Yanjun, Dalton Dayna S, Klein Barbara E K, Klein Ronald, Pinto Alex, Cruickshanks Karen J. Association of Cadmium and Lead Exposure With the Incidence of Contrast Sensitivity Impairment Among Middle-aged Adults.. JAMA ophthalmology. 2018. DOI: 10.1001/jamaophthalmol.2018.3931.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.